摘要
针对变频电机早期损坏的普遍特性,深入探讨了变频电机绝缘的损坏机理,提出了选用抗电晕性能好的电磁线、以及采用无气隙绝缘的主绝缘等措施,为早期损坏提供了有效的解决方案。
Aim at the general characteristics of variable frequency motor early damage,the principle of variable frequency motor insulation damage was proposed. The choice of magnet wire,non-air-gap insulation of main insulation were put forward,provided effective solution for early damage.
出处
《电机与控制应用》
北大核心
2010年第7期64-66,共3页
Electric machines & control application
关键词
变频电机
绝缘损坏
措施
variable frequency motor
insulation damage
measure