摘要 某石化厂一台新建的芳烃抽提二甲苯塔进行水压试验时压力超载,造成设备筒体开裂、部分内支撑圈和外加强圈断裂、筒体产生塑性变形等损伤。通过对该设备的全面检验和分析评估,认为更换了其中的5个筒节后其整体安全性能尚能满足使用要求。通过事故分析,提出制造过程中应使内支撑圈的对接焊缝避开与筒体之间的角焊缝,以防止支撑圈的对接焊缝开裂扩展到筒体。 An xylene tower of a petrochemical plant was cracked on the wall by over-pressured hydrostatic test after its construction.The over-pressure also damaged the inner supporting and outer stiffening rings,caused plastic deformation to the cylinders.By overall inspection and safety assessment,the tower was considered to be conformity with the requirement to use.The economic lost was avoided from not rejecting the entire tower.The failure analysis also give the suggestion that the butt welding joint of the internal supporting ring should not connect to the fillet welding joint between the ring and cylinder,then the break of the butt-welding joint can be prevented from spreading to the cylinder.
出处 《石油化工设备》 CAS 2010年第B08期8-10,共3页 Petro-Chemical Equipment
关键词 水压试验 泄漏 表面裂纹 安全评估 支撑圈 hydrostatic test leakage surface crack safety assessment supporting ring
  • 相关文献

参考文献11

二级参考文献12

  • 1江镇海.中型尿素厂Φ1400合成塔腐蚀及防护[J].中氮肥,1996(2):11-16. 被引量:3
  • 2陈南平.机械工程与材料科学[J].机械工程材料,1994,18(1):7-7,53.
  • 3孙家孔.石油化工装置设备腐蚀与防护手册[M].北京:中国石化出版社,1996.286-316.
  • 4GB150—1998.钢制压力容器[S].北京:中国标准出版社,1998.
  • 5GB150-1998.钢制压力容器[S].[S].,..
  • 6JB4710-1992.钢制塔式容器[S].[S].,..
  • 7CVDA-1984.压力容器缺陷评定规范[S].[S].压力容器缺陷评定规范编制组,1984年..
  • 8[美]约翰 F H.压力容器部件结构设计与材料[M].北京:化学工业出版社,1985.
  • 9国家质量技术监督局.在用压力容器检验规程[M].北京:中国劳动社会保障出版社,1999.
  • 10API 581, Risk - based Inspection Base Resource Document [S]. 2000. 109-112.

共引文献733

同被引文献12

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部