期刊文献+

髋臼位相参数测量技术进展 被引量:12

下载PDF
导出
出处 《实用骨科杂志》 2010年第8期592-595,共4页 Journal of Practical Orthopaedics
基金 全军"十一五"课题(06G043)
  • 相关文献

参考文献24

  • 1毛宾尧.人工髋关节外科学[M].北京:人民卫生出版社,2001.215.
  • 2朱天岳.髋臼外展角和前倾角的动态测量及其临床意义[J].中华骨科杂志,1995,15(8):497-499. 被引量:44
  • 3索鹏,高建华,梅汉尧,陈永源,王浩杰,周永顶,陈坚,杨益.髋臼位相参数的测定方法及临床意义[J].中国骨伤,2003,16(12):711-713. 被引量:22
  • 4Miljkovic ND,Ercegan GM,Stulic RB.Computer aided evaluation of total hip prosthesis stability[J].Journal for Geometry and Graphics,1998,2(2):141-149.
  • 5Fabeck L,Farrokh D,Descamos PY,et al.A method to measure acetabular cup anteversion after total hip replacement[J].Acta Orthop Belg,1999,65(4):485-491.
  • 6Ackland MK,Bourne WB,Uhthoff HK.Anteversion of the acetabular cup.Measurement of angle after total hip replacement[J].J Bone Joint Surg(Br),1986,68(3):409-413.
  • 7Jaramaz B,DiGioia AM,Blackwell M,et al.Computer assisted measurement of cup placement in total hip replacement[J].Clin Orthop Relat Res,1998,(354):70-81.
  • 8Komeno M,Hasegawa M,Sudo A,et al.Computed tomographic evaluation of component position on dislocation after total hip arthroplasty[J].Orthopedics,2006,29(12):1104-1108.
  • 9Mian SW,Truchly G,Pflum FA.Computed tomography measurement of acetabular cup anteversion and retroversion in total hip arthroplasty[J].Clin Orthop Relat Res,1992,(276):206-209.
  • 10Ybinger T,Kumpan W,Hoffart HE,et al.Accuracy of navigation-assisted acetabular component positioning studied by computed tomography measurementsmethods and results[J].J Arthroplasty,2007,22(6):812-817.

二级参考文献31

  • 1朱天岳.髋臼外展角和前倾角的动态测量及其临床意义[J].中华骨科杂志,1995,15(8):497-499. 被引量:44
  • 2Zhu TY. Zhonghua Guke Zazhi. 1995;15(8): 497-499.
  • 3Jamali AA, Mladenov K, Meyer DC, et al. Anterior pelvic radiographs to assess acetabular retroversion: high validity of the cross-over-sign. J Orthop Res. 2007;25:758-765.
  • 4Siebenrock KA, Kalbermatten DF, Ganz R. Effect of pelvic tilt on acetabular retroversion: a study of pelves from cadavers. Clin Orthop Relat Res. 2003;407:241-248.
  • 5Tannast M, Zheng G, Anderegg C, et al. Tilt and rotation correction of acetabular version on pelvic radiographs. Clin Orthop Relat Res. 2005;438:182-190.
  • 6NadzadiME, Pedersen DR, Yack H J, et al. Kinematics, kinetics,and finite element analysis of common place maneuvers at risk for total hip dislocation. J Biomech. 2003;36:577-591.
  • 7Jolles BM, Zangger P, Leyvraz PF. Factors presdisposing to dislocation after primary total hip prosthesis. J Arthroplasty. 2002; 17:282-288.
  • 8Del Schutte H, Lipman A J, Bannar SM, et al. Effects of acetabular abduction on cup wear rates in total hip arthroplasty. J Arthroplasty. 1998; 13:621-626.
  • 9Kennedy JG, RogersWB, Soffe KE, et al. Effect of acetabular component orientation on recurrent dislocation, pelvic osteolysis, polyethylene wear, and component migration. J Arthroplasty. 1998 13: 530-534.
  • 10Yoder SA, Brand RA, Pedersen DR, et al. Total hip acetabular component position affects component loosening rates. Clin Orthop Relat Res. 1988;228: 79-87.