摘要
介绍了通过修改程序解决国外某程控钻孔机存长期在的误动作问题的方法,并分析了二线制传感器存在的缺陷,对解决类似问题提出了启示。
This paper introduces the solution existence of a foreign program-controlled drilling machine for 19 years malfunction problem by modifying the procedure, and analyzed the process of two-wire sensors defects, on the revelation made to solve similar problems.
出处
《工程建设与设计》
2010年第9期82-85,共4页
Construction & Design for Engineering
关键词
钻孔机
二线制传感器
程控设备
故障分析
drilling machine
two-wire sensors
program-controlled equipment
Faults analyses