摘要
从运行管理上对武钢自备电厂WGZ670/13.7-8型锅炉前屏过热器爆管原因进行了分析,并提出了预防的对策。
Causes bring on the burst tube in the front screen overheater of WGZ670/13.7-8 type boiler at the Selfbuilt Power Plant by WISCO are analyzed and preventatives raised in the paper.
出处
《武钢技术》
CAS
1999年第3期52-54,共3页
Wisco Technology
关键词
锅炉
金相分析
过热器
过热爆管
电站锅炉
boilermetallographical analysisoverheaterburst tube due to overheat