摘要
提出了薄层树脂相光度法测定锡的操作条件采用在0.1 mol·L-1 的介质中,以水扬基萤光酮(SAF)为显色剂,用阴离子交换树脂吸着测定锡灵敏度比溶液光度法提高80 倍,除As(Ⅲ) 、Sb( Ⅲ) 、Fe( Ⅲ)外,其余共存离子基本无干扰实测了天然水中锡,加标回收率93% ~99%
In this paper,operation condition of the thinlayer resin-phase spectrophotometry determination of trace tin has been developed determination of traces tin in hydrochloric acid medium with SAF for thiazolylazo reagent and anion exchange-resin to adsorptive. The sensitivity is 80 time as high as the solution spectrophotomtetric. Besides As?、Sb?、Fe?,the other ion don′t disturb busicaly.The method has been used to determine fin in water which give a recovery between of 93%~99%.
出处
《平顶山师专学报》
1999年第2期50-52,共3页
Journal of Pingdingshan Teachers College
关键词
薄层树脂
光度法
锡
测定
固体光度法
thin-layer ursin-phase spectrophotometry Tin determination