导出
摘要 介绍了用于非均匀放射性核废物无损测量层析γ扫描技术的原理和方法,并对标准200 L核废物钢桶样品进行了实际测量,采用152Eu作为透射源而实现了层析γ扫描重建的全过程,采用极坐标的体素划分形式和MCNP程序对系统进行效率刻度,分别采用代数迭代法和最大似然重建算法进行了透射和发射重建,得到了线性衰减系数与活度的分布图,并与分段γ扫描的测量结果加以对比.结果表明,层析γ扫描技术的重建结果明显好于分段γ扫描,其与真实值的偏差在10%以内,从而验证了极坐标划分和重建算法的可行性. The principle of tomographic gamma scanning(TGS) method for nondestructive assay of heterogeneous radioactive waste was described.An experiment of a 200 liter drum detection was conducted using the radioisotope()~(152)Eu as the transmission source.A polar voxel representation was used,and the efficiency matrix was calculated by MCNP codes.The algebraic reconstruction technique and maximum likelihood expectation-maximization method were adopted for transmission and emission reconstruction to get the distribution of linear attenuation coefficient and radioactivity,respectively.The TGS results are obviously better than segmented gamma scanning(SGS) results,fitting the real activity very well with a relative error less than 10%.The results indicate that the polar voxel representation and reconstruction algorithms are feasible.
出处 《上海交通大学学报》 EI CAS CSCD 北大核心 2010年第9期1287-1291,1296,共6页 Journal of Shanghai Jiaotong University
基金 国家自然科学基金项目(10675084)
关键词 层析γ扫描 图像重建 放射性探测 核废物 tomographic gamma scanning(TGS) image reconstruction radioactivity detection radioactive waste
  • 相关文献

参考文献10

  • 1杨明太,张连平.桶装核废物的非破坏性分析[J].核电子学与探测技术,2003,23(6):600-603. 被引量:19
  • 2Estep R J,Prettyman T H,Sheppard G A.Tomographic gamma scanning to assay hterogeneous radioactive waste[J].Nuclear Science and Engineering,1994,118:145-152.
  • 3Ramkumar V,Marcel Villani,Stephen C,et al.An integrated tomographic gamma scanning system for nondestructive assay of radioactive waste[J].Nuclear Instruments and Methods in Physics Research A,2007,579(1):375-379.
  • 4成雨,翁文庆,白云飞,王德忠,杨永亮,张勇.层析γ扫描技术效率矩阵计算模型分析与修正[J].上海交通大学学报,2008,42(9):1471-1473. 被引量:3
  • 5张全虎,杨道军,何彬,李泽,顾忠茂,钱绍钧.层析γ扫描中的探测效率刻度[J].原子能科学技术,2008,42(11):1043-1047. 被引量:6
  • 6张全虎,郭春营,马文彦,李泽,顾忠茂,钱绍钧.层析γ扫描透射测量的计算机模拟研究[J].原子能科学技术,2008,42(12):1139-1142. 被引量:2
  • 7翁文庆,王德忠,张勇,刘诚,杨永亮.层析γ扫描透射图像重建算法研究[J].核技术,2008,31(5):396-400. 被引量:5
  • 8Parker J L.The use of calibration standards and the correction for sample selfattenuation in gammaray nondestructive assay[R].Los Alamos National Laboratory Document,LA10045,1986.
  • 9Dung T Q.Calculation of the systematic error and correction factors in gamma waste assay system[J].Annals of Nuclear Energy,1997,24(1):33-47.
  • 10Tom H,Richard L,Manbir S,et al.Fast MLE for SPECT using an intermediate polar representation and a stopping criterion[J].IEEE Trans on Nuclear Science,1988,35(1):615-619.

二级参考文献16

  • 1张斌全,马吉增,程建平,刘立业,毛永.蒙特卡罗方法计算用于低能光子测量的高纯锗探测器的效率[J].核电子学与探测技术,2005,25(3):274-277. 被引量:26
  • 2Karamanis D. Efficiency simulation of HPGe and Si (Li) detectors in γ- and X-ray spectroscopy[J]. Nuclear Instruments and Methods in Physics Research, 2003, A505:282-285.
  • 3ESTEP R J, PRETTYMAN T H, SHEPPARD G. Tomographic gamma scanning to assay heterogeneous radioactive waste[J]. Nuclear Science and Engineering, 1994, 118: 145-152.
  • 4CAMP D C, MARTZ H E, ROBERSON G P, et al. Nondestructive waste-drum assay for transuranic content by gamma-ray active and passive computed tomography[J]. Nuclear Instruments and Methods in Physics Research A, 2002, 495: 69-83.
  • 5KAK A C, SLANEY M. Principles of computerized tomographic imaging[M]. New York: IEEE Press, 1987.
  • 6ROBERT J, ESTEP T H, PRETTYMAN S G. Tomographic gamma scanning to assay heterogeneous radioactive waste[J]. Nuclear Science and Engineering, 1994, 118: 145-152.
  • 7罗杰斯DF.计算机图形学的算法基础[M].北京:科学出版社,1987..
  • 8李德平 潘自强 著.辐射防护手册第一分册[M].北京:原子能出版社,1987.215.
  • 9Estep R J, Prettyman T H, Sheppared G A. Nucl Sci Eng, 1994, 118:145-152.
  • 10张全虎.层析γ扫描重建技术(TGS)的研究:[学位论文].北京:中国原子能科学研究院,2004.

共引文献24

同被引文献145

  • 1刘诚,王德忠,李厚文,白云飞,钱楠,张适,张继革.基于双探测器校正的分段γ扫描技术研究[J].核技术,2010,33(5):342-345. 被引量:7
  • 2张庆,古度意彦.HPGe探测器测量低能γ射线^(241)Am的研究[J].核电子学与探测技术,2004,24(5):498-501. 被引量:5
  • 3朱荣保,谭亚军,袁晓鑫,吕钊,曹斌,吴昕,程炳皓,许晓东,江金才.大型高分辨分段γ扫描装置的研制[J].原子能科学技术,1994,28(1):16-25. 被引量:13
  • 4谭亚军,朱荣保,吴昕,程炳皓,袁晓鑫,江金才.分段γ扫描装置数据获取与处理软件系统的研制[J].原子能科学技术,1994,28(1):26-31. 被引量:8
  • 5GB9133-1995.放射性废物的分类[S].[S].,..
  • 6Estep R J, Prettyman T H, Sheppard G A. Tomo graphic gamma scanning to assay hterogeneous radio active waste [J]. Nuclear Science and Engineering, 1994, 118:145-152.
  • 7Ramkumar V, Marcel Villani, Stephen C, et al. An integrated tomographic gamma scanning system for non destructive assay of radioactive waste[J]. Nucle- ar Instruments and Methods in Physics Research A, 2007,579:1):375 379.
  • 8Min Chan Kim, Kyung Youn Kim, Kyung Jin Lee, et al. Electrical impedance imaging of phase boundary in two-phase systems with adaptive mesh regeneration technique[J]. International Communications in Heat and Mass Transfer, 2005, 32(7): 954-963.
  • 9Wang Hua-xiang, Tang Lei, Cao Zhang. An image reconstruction algorithm based on total variation with adaptive mesh refinement for ECT[J]. Flow Measure- ment and Instrumentation, 2007, 18(5-6) : 262-267.
  • 10Zhu Hong-qing, Shu Hua-zhong, Zhou Jian, et al. Conditional entropy maximization for PET image re- construction using adaptive mesh model[J]. Comput- erized Medical Imaging and Graphics, 2007, 31 (3) : 166 177.

引证文献9

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部