摘要
西安某工厂生产车间要求设计集中式空调系统,针对达到规范所要求的室内温湿度和适当放宽室内温湿度(在人体舒适区域内)时,提出了传统机械制冷空调方案、蒸发冷却与机械制冷结合的空调方案及蒸发冷却空调方案,并根据西安气象参数计算出各种空调方案的制冷量、耗电量及节能情况,得出了应用蒸发冷却空调的可行性及节能效果。
Designing a centralized air-conditioning system for a factory workshop in Xi′an.Meet specification requirements for the indoor temperature and humidity or when relaxation them(people still feel comfortable),put forward the traditional mechanical refrigeration air-conditioning program、evaporative cooling and mechanical refrigeration combination of air-conditioning program and evaporative cooling air-conditioning program.We can conclud that all kinds of air-conditioning program cooling capacity,power consumption and energy-saving situation is calculated in accordance with Xi′an meteorological parameters and application of evaporative cooling air-conditioning is feasibility and energy-saving.
出处
《制冷》
2010年第3期68-71,共4页
Refrigeration
关键词
集中空调系统
蒸发冷却空调
机械制冷
蒸发冷却
能效比EER
节能
Central air-conditioning system
Evaporative cooling air-conditioning
Mechanical refrigeration
Evaporative cooling
Energy Efficiency Ratio EER