摘要 提出一种新型的混合装配式短肢墙,并采用有限元软件DRAIN-2DX编制相应的程序对一榀装配式剪力墙进行静力弹塑性分析,结果表明,随着各极限状态相继出现,结构的刚度不断退化,至连梁软化,趋于平稳;结构侧移曲线为上部有剪切段的弯剪形;在加载过程中,结构的耦联率基本保持不变,耦联率不宜过大。结构具有较好的延性和良好的抗震性能。 In this paper,a new kind of hybrid assembly short-pier wall was proposed,and a short pier wall was studied by using the finite element DRAIN-2DX and a computer code developed.The results shows that the stiffness of the structure degenerated as all limit state appeared in succession,until the coupling beams got soften;the sequence associated with the lateral curve of the structure;throughout the process of loading the coupling rate basically unchanged,but the value should not be too large.The structure has good ductility and anti-seismic performance
出处 《江苏建筑》 2010年第5期23-25,共3页 Jiangsu Construction
关键词 混合装配 剪力墙 推覆 hybrid assembly short-pier wall pushover
  • 相关文献

参考文献9

  • 1孙巍巍,孟少平,吴京.后张无粘结预应力混合装配式短肢剪力墙静力弹塑性分析[J].工程抗震与加固改造,2007,29(5):35-38. 被引量:2
  • 2Prakash V,Powell G H,Campbell S.DRAIN-2DX base program description and user uide,verl.10[R].Technieal Report UCB/SEMM-93/17.Department of Civil University of California,Berkeley, 1993.
  • 3StefanoPampanin, M.J.NigelPriestley, S.Sritharan. Analytical modeling of seismic behavior of precast concrete frames designed with ductile connections [J]. Journal of Earthquake Engineering, 2001, 5(3):329-367.
  • 4Mandy EI-Sheikh, Stephen Pessiki, Richard Sause, et al. Moment rotation behavior of unbonded post-tensioned precast concrete beam-column connections [J].ACI Structural Journal, 2000, 97(1):122-132.
  • 5Mander J B, Priestley M J N, Park R. Theoretical stress- strain model for confined concrete. Journal of the structural division, ASCE, 1988, 114(8):1804-1826.
  • 6GB50010-2002混凝土结构设计规范[S].中国建筑工业出版社,2002.
  • 7Yahya C.Kurama, Qiang Shen.Posttensioned hybrid Coupled walls under lateral loads [J].Journal of structural Engineering, 2004, 130(2):297-309.
  • 8蔡小宁,孟少平,孙巍巍.后张无粘结预应力装配式短肢墙破坏形态研究[J].工程抗震与加固改造,2009,31(1):70-73. 被引量:5
  • 9Canadian Standards Association (CSA).Design of Concrete Structures for Buildings.Canda, 1994.

二级参考文献16

  • 1彭飞,程文瀼,陆和燕,黄东升,汪杰,魏大平.短肢剪力墙的定义[J].东南大学学报(自然科学版),2007,37(2):186-189. 被引量:19
  • 2Nakaki S D, Stanton J F and Sritharan S. An overview of the PRESSS five-story precast test building [J]. PCI Journal, 1999,44(2) :26 - 39
  • 3ACI Innovation Group (ACI T1.2-03 ). Special hybrid moment frames composed of discretely jointed precast and pest-tensioned concrete members[ S]. 2003
  • 4Stanton J F, Nakaki S D. Design guidelines for precast concrete seismic structural systems[ R]. PRESSS report NO. 01/03-09, Department of Civil Engineering, University of Washington Seattle, 2002
  • 5Cheok G,Stone W. Performance of 1/3-scale model precast concrete beam-column connection subjected to cyclic inelastic loads-report No 4 [B]. NISTIT 5436, NIST, Gaithersburg, MD, 1994
  • 6Nakaki S D, Stanton J F and Sritharan S. An overview of the PRESSS five-story precast test building [ J]. PCI Journal, 1999, 44(2) :26-39.
  • 7ACI Innovation Group. ACI T1. 2-03. Special hybrid moment frames composed of discretely jointed precast and post-tensioned concrete members[ S]. 2003.
  • 8Cheok G, Stone W. Performance of 1/3-scale model precast concrete beam-column connection subjected to cyclic inelastic loads-report No 4 [ R ]. NISTIT 5436, NIST, Gaithersburg, MD, 1994.
  • 9Stanton J F, Nakaki S D. Design guidelines for precast concrete seismic structural systems[ R]. PRESSS report No. 01/03-09. Department of Civil Engineering, University of Washington, Seattle, 2002.
  • 10Prakash V, Powell G H, Campbell S. DRAIN-2DX Base Program Description and User Guide, ver 1. 10 [ R ]. Technical Report, UCB/SEMM-93/17. Dept. of Civil Engineering, University of California, Berkeley, 1993.

共引文献33

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部