基于简比的C臂图像标记点自动匹配方法 被引量:1

Automatic Matching Technology for C-arm Image Marked Points Based on Simple Ratio
下载PDF
导出
摘要 针对C形臂X光机图像校正与标定过程中存在大量标记点需要自动对应问题,提出一种基于简比的标记点图像坐标与世界坐标自动对应方法。首先在自行设计的双层校准模板的底层模板上制作3个大的标记点,以在校准模板及其C臂图像上建立仿射坐标系;其次通过建立平面单应关系,将利用形态学方法提取出的校准模板的标记点图像坐标转换为仿射坐标;然后利用仿射变换共线三点简比不变性质,将图像仿射坐标归整,实现与校准模板标记点的自动对应;最后利用标记点投影性质区分上下两层标记点,并消除因投影失真产生的错误对应,从而实现标记点图像坐标与空间点坐标的自动准确对应。大量的测试试验表明,该方法稳定性好、鲁棒性强,具有实现简单、无需人工介入等优点,可应用于基于C臂X光图像的手术导航系统中。 This study is aimed to achieve the automatic correspondence of large numbers of markers between the image coordinates and world coordinates during the C-arm X-ray image correction and calibration.An automatic matching method based on simple ratio was proposed.At first,three large markers were made in the lower template of the self-designed double calibration template to establish the affine coordinate system on the calibration template and its X-ray image.Secondly,the markers' image coordinates were converted into affine coordinates through homography after they were extracted from X-ray images by morphology methods.Then the image affine coordinates of these markers were rounded to automatically correspond to the spatial markers according to the invariant of affine transformation.Finally,the upper layer markers were distinguished by the projection properties,and the corresponding errors were corrected meantime.Experimental results showed that the proposed method was stable and robust.Besides,it is simple to achieve and need no human intervention.The method could be applied to the surgical navigation system based on C-arm X-ray images.
出处 《中国生物医学工程学报》 CAS CSCD 北大核心 2010年第5期654-659,共6页 Chinese Journal of Biomedical Engineering
基金 国家自然科学基金资助项目(60905021) 国家高技术研究发展(863)计划(2007AA04Z246 2009AA044002-1) 高等学校博士学科点专项科研基金(20091102120028)
关键词 C臂标定 校准模板 自动匹配 简比 C-arm calibration calibration template automatic matching simple ratio
  • 相关文献

参考文献13

  • 1Marwan S,Hans U,Staubli M D,et al,Clinical integration of computer-assisted technology for arthroscopic anterior cruciate ligament reconstruction[J].Operative techniques in orthopaedics,2000,10(1):40-49.
  • 2刘文勇,王满宜,王田苗,胡磊.计算机辅助髓内钉远端锁定系统误差分析[J].北京航空航天大学学报,2004,30(9):850-854. 被引量:5
  • 3黄惠芳,张璞.基于形态学和多项式的数字减影血管造影图像几何失真的校正[J].生物医学工程研究,2008,27(1):31-35. 被引量:4
  • 4Sati M,Staubli HU,Bouquin Y,et al.Real-time computerized in situ guidance system for ACL graft placement[J].Computer Assisted Surgery,2002,7(1):25-40.
  • 5金玉博.医用X射线影像增强器的原理和检测[J].中外医疗,2008,27(21):165-166. 被引量:2
  • 6Forlani C,Ferrigno G.Automatic real-time XRII local distortion correction method for digital linear tomography[A].In:Alexandrov VN,eds.Proceedings of International Conference on Computational Science[C].Heidelberg:Springer Berlin,2001.23-26.
  • 7Cerveri P,Forlani C,Borgheze NA.Distortion correction for x-ray image intensifiers:Local unwarping polynomials and RBF neural networks[J].Medical Physics,2002,29 (8):1759-1771.
  • 8Gronenschild E.Correction for geometric image distortion in the x-ray image chain:local technique versus global technique[J].Medical Physics,1999,26 (12):2602-2616.
  • 9Slomczy kowski M,Hofstetter R,Strauss M,et al.Fluoroscopybased surgical navigation-concept and possible clinical applications[A].In:Nolte LP,Ganz R,eds.Computer Assisted Orthopedic Surgery[C].Bern:Hogrefe and Huber Publishers,1999.206-217.
  • 10Livyatan H,Yaniv Z,Joskowicz L.Robust automatic C-arm calibration for fluoroscopy-based navigation:A practical approach[A].In:Dohi T,Kikinis R,eds.Fifth International Conference on Medical Image Computing and Computer-Assisted Intervention[C].Piscataway:IEEE Press,2002.60-68.

二级参考文献27

  • 1蒋高民,刘国浩.高校影像教学中X线的合理使用与防护[J].中国医药导报,2007,4(07S):160-161. 被引量:1
  • 2Livyatan H,Yaniv Z,Joskowicz L.Robust Automatic C-arm Calibration for Fluoroscopy-based Navigation:A Practical Approach[C]//Proc,of the 5th Int'l.Conf.on Medical Image Computing and Computer-aided Intervention.Tokyo,Japan:[s.n.],2002.
  • 3Otsu N.A Threshold Selection Method from Gray-level Histograms[J].IEEE Transactions on Systems,Man,and Cybernetics,1979,9(1):62-63.
  • 4Theodoridis S,Koutroumbas K.Pattern Recognition[M].北京:机械工业出版社,2003.
  • 5Gronenschild E.The Accuracy and Reproducibility of a Global Method to Correct for Geometric Image Distortion in the X-ray Imaging Chain[J].Medical Physics,1997,24(12):1875-1888.
  • 6Sadowsky O.Contact and Image-based Rigid Registration in Computer-assisted Surgery:Materials,Methods,and Experimental Results[D].Jerusalem,Israel:The Hebrew University of Jerusalem,2001.
  • 7Faugeras O.Three-dimensional Computer Vision:A Geometric Viewpoint[M].Cambridge,Massachusetts,USA:MIT Press,1993.
  • 8[1]Slomczykowski M, Hofstetter R, Strauss M, et al .Fluoroscopy-based surgical navigation-concept and possible clinical applications [A].In:Nolte L P, Ganz R, eds.Computer Assisted Orthopedic Surgery (CAOS)[C].Bern:Hogrefe & Huber Publishers, 1999.206~217
  • 9[2]Gross M H.Computer graphics in medicine:from visualization to surgery simulation [J].Computer Graphics (ACM), 1998, 32(1):53~56
  • 10[3]Zhu Y, Phillips R, Griffiths J G, et al .Recovery of distal hole axis in intramedullary nail trajectory planning [A].In:Proceeding of the 2001 IEEE International Conference on Robotics & Automation[C].Seoul, 2001.1561~1566

共引文献12

同被引文献14

  • 1刘文勇,王满宜,王田苗,胡磊.计算机辅助髓内钉远端锁定系统误差分析[J].北京航空航天大学学报,2004,30(9):850-854. 被引量:5
  • 2王田苗,张家磊,刘忠军,胡磊,栾胜.基于力反馈的脊柱外科机器人系统的设计与实现[J].机器人,2007,29(5):463-468. 被引量:4
  • 3Meng C, Zhang J, Eiu D, et al. A remote-controlled vas- cular interventional robot: system structure and imageguidance. The International Journal of Medical Robotics and Computer Assisted Surgery, 2013, 9(2): 230-239.
  • 4Wang T, Zhang D, Da L. Remote-controlled vascular in- terventional surgery robot. The International Journal of Medical Robotics and Computer Assisted Surgery, 2010, 6 (2) : 194-201.
  • 5Sati M, Staubli H U, Bouquin Y, et al. Real-time com- puterized in situ guidance system for ACL graft place- ment. Computer Assisted Surgery, 2002, 7 ( 1 ) : 25- 40.
  • 6Schmidgunst C, Ritter D, Lang E. Calibration model of a dual gain fiat panel detector for 2D and 3D X-ray ima- ging. Medical physics, 2007, 34 (9) : 3649-3664.
  • 7Mitsehke M M, Navab N. Optimal configuration for dy- namic calibration of projection geometry of X-ray C-arm systems. In. Proceedings of the IEEE Workshop on Math- ematical Methods in Biomedical Image Analysis, Hilton Head Island, USA, 2000. 204-209.
  • 8Meng C, Zhang J, Zhou F G, et al. New method for geo- metric calibration and distortion correction of conventional C-arm. Computers in Biology and Medicine, 2014, 52 (3) : 49-56.
  • 9Guti6rrez L F, Ozturk C, McVeigh E R, et al. A practi- cal global distortion correction method for an image inten- sifier based X-ray fluoroscopy system. Medical physics, 2008, 35(3): 997-1007.
  • 10Cerveri P, Forlani C, Borghese N A, et al. Distortion correction for X-ray image intensifiers: Local unwarping polynomials and RBF neural networks. Medical physics, 2002, 29(8) : 1759-1771.

引证文献1

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部