摘要 目的 比较金属对金属(MOM)大直径全髋关节置换术后与金属对聚乙烯(MOP)全髋关节置换术后的近期疗效.方法 2007年6月至2008年12月采用髋关节后外侧入路对30例(30髋)进行MOM大直径全髋关节置换术(MOM组),男12例,女18例;平均年龄60.3岁;平均体质量指数23.7 kg/m2;术前Harris评分平均为(36±15)分.同期采用后外侧入路对30例(30髋)进行MOP全髋关节置换术(MOP组),男9例,女21例;平均年龄62.4岁;平均体质量指数23.4 kg/m2;术前Harris评分平均为(34±17)分.对两组患者的术后功能恢复及影像学进行比较.结果 术后随访12~18个月(平均14.4个月),两组患者均未发生感染、骨折脱位及神经损伤等并发症,MOP组有1例患者术后2个月形成深静脉血栓.术后1、3、6、12个月Harris评分MOM组平均分别为(86±3)、(90±3)、(95±4)、(92±4)分,MOP组平均分别为(78±4)、(84±3)、(90±4)、(92±4)分.术后1、3、6个月两组Harris评分比较差异均有统计学意义(P<0.05).术后MOM组髋关节总活动范围平均为239.2°±21.9°,屈髋平均为135.4°±10.9°;MOP组髋关节总活动范围平均为190.1°±16.7°,屈髋平均为95.3°±11.3°,差异有统计学意义(P<0.05).结论 MOM大直径全髋关节置换相比传统MOP全髋关节置换短期疗效好,其中远期疗效需进一步观察. Objective To compare the short-term results of metal-on-metal (MOM) and metal-on-polyethylene (MOP) bearing surfaces in total hip replacement (THR). Methods Thirty cases, 12 males and 18 females, received MOM THR through a posterolateral surgical approach from June 2007 to December 2008. Their mean age was 60.3 years, mean body mass index (BMI) was 23.7 g/m2 and mean Harris score was 36 ± 15 preoperatively. For comparison, another 30 cases, 9 males and 21 females, received MOP THR through the same approach at the same period. Their mean age was 62.4 years, mean BMI was 23.4 kg/m2 and mean Harris score was 34 ± 17 preoperatively. The 2 groups were compared in terms of hip functional recovery and radiographic examination. Results All patients obtained an average follow-up of 14.4 months (range, 12 to 18 months) . No infection, fracture or neurovascular injury occurred in either group. There were one deep venous thrombosis and one dislocation in the MOP group. The average Harris scores at 1, 3, 6, 12 months postoperatively were respectively 78 ±4, 84 ±4, 90 ±3, 92 ±4 for the MOP group and 86 ± 3, 90 ± 3, 95 ± 4, 95 ± 3 for the MOM group. The differences between the 2 groups were significant at 1, 3, 6 months ( P 〈 0.05) but insignificant at 12 months ( P 〉 0.05). In the MOM group,the total range of hip motion averaged 239.2°± 21.9° and the hip inflexion averaged 135.4°± 10.9°. In the MOP group, the total range of hip motion averaged 190.1°± 16.7° and the hip inflexion averaged 95.3°± 11.3°. The differences between the 2 groups were significant ( P 〈 0.05). Conclusion On a short-term basis, MOM THR may be better than MOP THR, but the medium and long-term results of MOM bearing surfaces still need further investigation.
出处 《中华创伤骨科杂志》 CAS CSCD 2010年第10期940-944,共5页 Chinese Journal of Orthopaedic Trauma
关键词 关节成形术 置换 假体和植入物 治疗结果 Arthroplasty, replacement, hip Prostheses and implants Treatment outcome
  • 相关文献

参考文献16

  • 1徐又佳,瞿玉兴,王向利,沈光思,董启榕,郑祖根.金属大头髋(ASR^TM XL)的临床应用特点[J].中华创伤杂志,2008,24(12):978-981. 被引量:1
  • 2Pedersen DR,Callaghan JJ,Johnston TL,et al.Comparison of femoral head penetration rates between cementless acetabular components with 22-mm and 28-mm heads.J Arthroplasty,2001,16:111-115.
  • 3Hedlundh U,Ahnfelt L,Hybbinett CH,et al.Dislocations and the femoral head size in primary total hip arthroplasty.Clin Orthop Relat Res,1996,(333):226-233.
  • 4Peters CL,McPherson E,Jackson JD,et al.Reduction in early dislocation rate with large-diameter femoral heads in primary total hip arthroplasty.J Arthroplasty,2007,22:140-144.
  • 5Dowson D,Hardaker C,Flett M,et al.A hip joint simulator study of the performance of metal-on-metal joints.Part Ⅰ:The role of mater als,J Arthoplasty,2004,19:118-123.
  • 6Goldsmith AA,Dowson D,Isaac GH,et al.A comparative joint simulator study of the wear of metal-on-metal and alternative material combinations in hip replacements.Proc Inst Mech Eng H,2000,214:39-47.
  • 7Burroughs BR,Hallstrom B,Golladay GJ,et al.Range of motion and stability in total hip arthroplasty with 28-,32-,38-and 44-mm femoral head sizes.J Arthroplasty,2005,20:11-19.
  • 8Malik A,Maheshwari A,Dorr LD.Impingement with total hip replacement.J Bone Joint Surg(Am),2007,89:1832-1842.
  • 9Hart AJ,Buddhdev P,Winship P,et al.Cup inclination angle of greater than 50 degrees increases whole blood concentrations of cobalt and chromium ions after metal-on-metal hip resurfacing.Hip Int,2008,18:212-219.
  • 10Walter LR,Marel E,Harbury R,et al.Distribution of chromium and cobalt ions in various blood fractions after resurfacing hip arthroplasty.J Arthroplasty,2007,23:814-821.

二级参考文献9

  • 1Dowson D, Hardaker C, Flett M, et al. A hip joint simulator study of the performance of Metal - on - Metal joints ( Part Ⅱ: Design). J Arthroplasty, 2004, 19(8 Suppl 3) :124 -130.
  • 2Dowson D, Hardaker C, Flett M, et al. A hip joint simulator study of the performance of metal - on - metal joints ( Part Ⅰ: The role of materials). J Arthroplasty, 2004, 19 ( 8 Suppl 3 ) : 118 - 123.
  • 3Seholes SC, Green SM, Unsworth A. The wear of metal - on - metal total hip prostheses measured in a hip simulator. Proc Inst Mech Eng, 2001, 215(6) :523 -530.
  • 4Nevelos J, Shelton JC, Fisher J. Metallugical considerations in the wear of metal - on - metal hip bearings. Hip Internation, 2004, 14(1) :1-10.
  • 5Smith SL, Dowson D, Goldsmith AA. The lubrication of metal - on - metal total hip joints : a slide down the Stribeck curve. J Engin Tribo, 2001, 215(5) :483 -493.
  • 6Amstutz HC, Campbell P. Metal- on- metal hip resurfacing: what have we learned? Instr Course Lect, 2007, 56:149 -161.
  • 7Witzleb WC, Hanisch U, Kolar N, et al. Neo - capsule tissue reactions in metal - on - metal hip arthroplasty. Acta Orthop, 2007, 78(2) :211 -220.
  • 8Cosmi F, Hoglievina M, Faneellu G, et al. A finite element method comparison of wear in two metal - on - metal total hip prostheses. Proe Inst Mech Eng, 2006, 22(8) :871 -879.
  • 9周勇刚,王岩,何登伟,刘芙进.金属与金属相关节的人工髋关节的发展[J].当代医学,2001,7(10):68-70. 被引量:3

共引文献1

同被引文献38

  • 1王旭,顾湘杰,鲍根喜,陈飞雁,黄加张.陶瓷-陶瓷人工髋关节初步应用结果[J].骨与关节损伤杂志,2004,19(7):448-450. 被引量:11
  • 2Harris WH.Traumatic arthritis of the hip after dislocation and acetabular fractures:treatment by mold arthroplasty.An end-result study using a new method of result evaluation.J Bone Joint Surg Am.1969;51(4):737-755.
  • 3Dowson D,Hardaker C,Flett M,et al.A hip joint simulator study of the performance of metal-on-metal joints.Part I:The role of materials.J Arthroplasty.2004;19:118-123.
  • 4Keegan GM,Learmonth ID,Case CP.Orthopaedic metals and their potential toxicity in the arthroplasty patient:A review of current knowledge and future strategies.J Bone Joint Surg(Br).2007;89:567-573.
  • 5Amstutz HC,Grigoris P. Metal on metal bearings in hip arthroplasty[ J].Clin Orthop Relat Res, 1996 , (329 Suppl) :SI 1-34.
  • 6Crawford R,Ranawat CS,Rothman RH. Metal on metal: is it worth therisk[ J]. J Arthroplasty,2010,25 (1 ) :1-2.
  • 7Berton C,Girard J,Krantz N,et al. The Durom large diameter head ace-tabular component : early results with a large-diameter metal-on-metalbearing[J].J Bone Joint Surg Br,2010,92(2) :202-208.
  • 8Dowson D,Hardaker C,Flett M,et al. A hip joint simulator study of theperformance of metal-on-metal joints:Part II:design[ J]. J Arthroplasty,2004,19(8 Suppl 3) : 124-130.
  • 9Streicher RM. Ceramic on ceramine articulation in THA[J].Journal of Bone and Joint Surgery-British Volume,2002.259.
  • 10Schwartz CJ,Bahadur S,Mallappragada SK. Effect of cross linking and Pt-Zr quasicrystal fillers on the mechanical properties and wear resistance of UHMWPE for use in artificial joints[J].Wear,2007,(07):1072.doi:10.1016/j.wear.2006.10.023.

引证文献4

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部