期刊文献+

陶瓷人工关节研究进展 被引量:8

原文传递
导出
摘要 陶瓷人工关节假体具有耐磨、生物惰性等特点,临床上因其假体松动发生率较低而备受关节外科医生关注。陶瓷人工关节经历了四代工艺技术的改进,现已日趋完善。第一代人工陶瓷关节的应用从1974到1988年,第二代人工陶瓷关节的应用从1988年到1994年,第三代人工陶瓷关节从1994年开始一直应用至今,第四代人工陶瓷关节已于2003年开始应用于临床。人工陶瓷关节历经变迁,已在临床治疗方面取得了长足发展。本文就人工陶瓷关节在临床应用的现状和发展作一综述。
出处 《中华骨科杂志》 CAS CSCD 北大核心 2010年第11期1157-1160,共4页 Chinese Journal of Orthopaedics
  • 相关文献

参考文献37

  • 1Willmann G.Ceramic femoral head retrieval data.Clin Orthop Relat Res,2000(379):22-28.
  • 2Bierbaum BE,Nairus J,Kuesis D,et al.Ceramic-on-ceramic bearings in total hip arthroplasty.Clin Orthop Relat Res,2002(405):158-163.
  • 3Nizard R,Sedel L,Hannouche D,et al.Alumina pairing in total hip replacement.J Bone Joint Surg(Br),2005,87(6):755-758.
  • 4Masson B.Emergence of the alumina matrix composite in total hip arthroplasty.Int Orthop,2009,33(2):359-363.
  • 5Skinner HB.Ceramic bearing surfaces.Clin Orthop Relat Res,1999(369):83-91.
  • 6Zichner L,Lindenfeld T.In-vivo wear of the slide combinations ceramics-polyethylene as opposed to metal-polyethylene.Orthopade,1997,26(2):129-134.
  • 7Lewis PM,Al-Belooshi A,Olsen M,et al.Prospective randomized trial comparing alusina ceramic-on-ceramic with ceramic-onconventional polyethylene bearings in total hip arthroplasty.J Arthroplasty,2010,25(3):392-397.
  • 8Lachiewicz PF,Hubbard JB,Soileau ES.Polyethylene wear and osteolysis with a new modular titanium acetabular component:results at 7 to 13 years.J Arthroplasty,2008,23(7):971-976.
  • 9Milosev I,Trebse R,Kovac S,et al.Survivorship and retrieval analysis of sikomet metal-on-metal total hip replacements at a mean of seven years.J Bone Joint Surg(Am),2006,88(6):1173-1182.
  • 10Chevalier J,Cales B,Drouin JM.Low-temperature aging of YTZP ceramics.J Am Ceram Soc,1999,82(8):2150-2154.

同被引文献106

  • 1冯建翔,何志勇,狄正林,章军辉.非骨水泥型全髋关节假体治疗强直性脊柱炎[J].中国骨伤,2007,20(9):608-610. 被引量:9
  • 2Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures:treatment by mold arthroplasty. An end -result study using a new method of result evaluation [J]. J Bone Joint Surg Am,1969,51 (4):737 -755.
  • 3Savarino L, Padovani G, Ferretti M, et al. Serum ion levels after ceramic-on-ceramic and metal-on-metal total hip ar- throplasty: 8-year minimum follow-up [ J ]. J Orthop Res, 2008,26(12) :1569 - 1576.
  • 4Delaunay CP, Bonnomet F, Clavert P, et al. THA using metal- on-metal articulation in active patients younger than 50 years [ J ]. Clin Orthop Relat Res, 2008,466 ( 2 ) : 340 - 346.
  • 5Tateiwa T, Clarke IC, Williams PA, et al. Ceramic total hip arthroplasty in the United States:salety and risk issues re- visited [ J ]. Am J Orthop ,2008,37 ( 2 ) : 26 - 31.
  • 6Mai K, Hardwick ME, Walker RH, et al. Early dislocation rate in ceramic-on-ceramic total hip arthroplasty [J ]. HSS J,2008,4( 1 ) :10 - 13.
  • 7Choy WS, Kim KJ, Lee SK, et al. Ceramic-on-ceramic total hip arthro- plasty: minimum of six-year follow-up study. Clin Orthop Surg, 2013, 5(3): 174-179.
  • 8Schmalzried TP, Jasty M, Harris WH. Periprosthetic bone loss in total hi p arthroplasty. Polyethylene wear debris and the concept of the ef- fective joint space. J Bone Joint Surg (Am), 1992, 74(6): 849-863.
  • 9Sedel L. Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res, 2000, (379): 48-54.
  • 10Zha GC, Sun JY, Dong SJ. Less anterior knee pain with a routine lat- eral release in total knee arthroplasty without patellar resurfacing: a prospective, randomized study. Knee Surg Sports Traumatol Arthrosc, 2014, 22(3): 517-525.

引证文献8

二级引证文献43

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部