兔离体新鲜肝组织的电阻抗温度特性研究 被引量:7

Electric Impedance Temperature-resistant Characteristics in Fresh Rabbit Liver in Vitro
下载PDF
导出
摘要 目的:获得肝组织的电导率与温度的关系,为采用电阻抗成像法监测在肝肿瘤热疗时的体内温度奠定基础。方法:采用新鲜离体兔肝,通过模拟肝肿瘤热疗过程,四电极法阻抗盒测量兔肝在受热和冷却的2个阶段的多频电阻抗,研究兔肝组织的电阻抗与温度间的相应关系。结果:在58℃以下、f=1 kHz时,温度-电阻抗变化系数基本上在-1.0%~-2.2%波动。在58~69℃区间,温度-电阻抗变化系数从-2%快速变化至-14.7%。69、70、71℃等3个温度点的温度—电阻抗变化系数均保持在-14.7%附近。在71~76℃区间,温度-电阻抗变化系数从-14.7%快速变化至-1.0%。76℃以上,温度-电阻抗变化系数基本上为-1.0%。结论:兔肝细胞受热变性时电阻抗特性发生显著改变。在临床热疗中,有可能通过监测生物阻抗的改变来监测热疗时的温度。 Objective To obtain the relationship between conductivity and temperature of liver tissue in order to lay a foundation for monitoring the body temperature during the liver tumor thermotherapy with Electrical Impedance Tomography(EIT).Methods By simulating the course of liver tumor thermotherapy,the multi-frequency electrical impedance of fresh rabbit liver was measured by the four-electrode impedance box in the process of heating and cooling.The corresponding relationship of temperature and electrical impedance of rabbit liver was calculated.Results At the frequency of 1KHz,with temperature below 58℃,the Temperature-Impedance Variation Factor(TIVF)mainly fluctuated between-1.0%~-2.2%.From 58℃ to 69℃,TIVF rapidly changed from-2.0% to-14.7%.At 69℃,70℃ and 71℃,TIVF maintained around-14.7%.From 71℃ to 76℃,TIVF changed rapidly from-14.7% to-1.0%.TIVF was mainly-1% at temperature above 76℃.Conclusion Significant changes of electrical impedance characteristics occur when liver cells are denaturized by hyperthermia.In clinical therapy,it is possible to monitor temperature in hyperthermia by monitoring the changes of bio-impedance.
出处 《医疗卫生装备》 CAS 2010年第11期8-11,共4页 Chinese Medical Equipment Journal
基金 军队"十一五"攻关项目(08G115)
关键词 肿瘤热疗 温度 肝组织 电阻抗 hyperthermia temperature liver tissue impedance
  • 相关文献

参考文献16

  • 1Wessalowski R,Van Heek-Romanowski R,lssols HT,et al.Review:Estimated number of children with eligible for hyperthermia based on population and treatment-related criteria[J].Int J Hyporthermia,1999,15(6):455-466.
  • 2Van der Zee J,Gonzalez D,Van Rhoon G C,et al.Comparison of radiotherapy alone with radiotherapy plus hyperthermia in locally advanced pelvic tumours:prospective,randomized,multicentre trial[J].Lancet,2000,355(9 210):1 119-1 125.
  • 3吴水才,白燕萍,南群,夏雅琴.癌热疗中超声无创测温方法的研究[J].国外医学(生物医学工程分册),2002,25(1):35-38. 被引量:14
  • 4Young I R,Hand J W,Oatridge A,et al.Modeling and observation of temperature changes in vivo using MRI[J].MagnReson Med,1994,32(1):358-369.
  • 5Meaney P,Paulsen K,Hartov A,et al.Microwave imaging for tissue assessment:Initial evaluationin multi-target tissueequivalent phantoms[J].IEEE Trans BME,1996,43 (9):878-890.
  • 6Paulsen K,M oskowitz M,RyanT,et al.Initial in vivo experience with EIT as a thermal estimator during hyperthermia[J].Int J Hyperthermia,1996,12(5):573-591.
  • 7Griffiths H,Ahmed A.Applied potential tomography for noninvasive temperature mapping in hyperthermia[J].Clin Phys Physiol Mess,1987(8):147-153.
  • 8Conway J.Electrical impedance tomngraphy for thermal monitoring of hyperthermia treatment:an assessment using in vitro and in vivo measurements[J].Clin Phys Physiol Mess,1987(8):141-146.
  • 9Blad B,Persson B,Lindstrom K.Quantitative assessment of impedance tomography for temperature measurements in hyperthermia[J].International Journal of Hyperthermia,1992,8 (1):33-43.
  • 10Paulseu K D,Moskowitz M J,Ryan T P,et al.Initial in vivo experience with EIT as a thermal estimator during hyperthermia[J].Int J Hyperthermia,1996,12(5):573-591.

二级参考文献36

  • 1夏景林,任正刚,叶胜龙,干育红,王艳红,张博恒,邹静怀,陈漪,葛宁灵.肝癌射频消融治疗严重或少见并发症分析[J].中国微创外科杂志,2005,5(4):268-270. 被引量:16
  • 2董宝玮,梁萍.肿瘤热消融治疗:现状和展望[J].中华医学杂志,2006,86(12):793-796. 被引量:24
  • 3林征宇,武乐斌,李成利,毕万利,梁长虎.肝脏激光间质热消融治疗中组织温度变化规律的实验研究[J].医学影像学杂志,2006,16(9):982-985. 被引量:4
  • 4蒋力生,汪静,翟宏军,李宁,陈启锐.高强度聚焦超声治疗乳房纤维腺瘤临床分析[J].中国普外基础与临床杂志,2007,14(3):337-338. 被引量:2
  • 5Meaney P,Paulsen K,Hartov A,et al. Microwave imaging for tissue assessment :Initial evaluation in multitarget tissue-equivalent phantoms [J]. IEEE Trans BME, 1996,43(9): 878-890.
  • 6Diederich CJ,Nau WH,Deardorff DL,et al. MR thermal monitroring of ultrasound interstitial thermal therapy[J]. Proceedings of SPIE-The International Society for Optical Engineering, 1999,3594:178-184.
  • 7Paulsen K,Moskowitz M,Ryan T,et al. Initial in vivo experience with EIT as a thermal estimator during hyperthermia [J]. Int J Hyperthermia, 1996, 12 (5): 573-591.
  • 8Lu BY,Lin WL,Yang RS,et al. Temperature distributions of bone tumor therapy using scanned focused ultrasound system. Ann Int Conf IEEE Eng Med Biol,Atlanta, GA, USA. 1999,2:1272.
  • 9Singh VR,Yadav S. Non-invasive measurement of temperature in ultrasonic hyperthermia[C]. IEEE Engineering in Medicine & Biology Society 10th annual International Conference, New Delhi, India, 1998. 0850-0851.
  • 10Ueno S.Ultrasound thermometry in hyperthermia[C].Proc IEEE Ultrasonics symposium,Kawasaki,Japan.1990.1645-1692.

共引文献20

同被引文献60

引证文献7

二级引证文献17

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部