期刊文献+

硝酸银显色法测量混凝土氯离子表观扩散系数 被引量:4

MEASUREMENT OF CHLORIDE APPARENT DIFFUSION COEFFICIENT IN CONCRETE USING AgNO_3 COLORIMETRIC METHOD
原文传递
导出
摘要 研究了硝酸银显色法快速测量混凝土中氯离子表观扩散系数。将14组混凝土试件分别在16.5%与3.5%NaCl溶液中浸泡90d和300d,用AgNO_3显色法及NT Build 443法测量其氯离子表观扩散系数(D_A和D_N)。结果表明:用浸泡液浓度为表面氯离子浓度情况下,当表层氯离子浓度与浸泡液氯离子浓度相近时,D_A与D_N值相近;浸泡90 d时,一部分D_A与D_N值相近;浸泡300 d时,所有的D_A与D_N均十分相近。测量的表层氯离子浓度作为表面氯离子浓度时,所有D_A和D_N均十分接近。因此,合理确定表面氯离子浓度后,硝酸银显色法可以快速且较为精确地测量混凝土氯离子表观扩散系数。 A quick method for measurement of chloride apparent diffusion coefficient in concrete using AgNO_3 colorimetric method was investigated.14 batches of concrete specimens were respectively immersed in 16.5%and 3.5%NaCl solutions for 90 and 300 d. Their apparent Cl^-diffusion coefficients were measured by the AgNO_3 colorimetric method and NT Build 443 method(named as D_A and D_N).In the case of taking chloride concentration in the immersion solution as surface chloride concentration(c_s),when chloride concentrations in the surface layer and the immersion solution were similar,D_A and D_N,values were almost the same.After 90 d of immersion,part of D_A and D_N values were almost the same.After 300 d of immersion,all of D_A and D_N values were almost the same. When taking chloride concentration in the surface layer as the c_s,all of D_A and D_N values were almost the same.Therefore,after determination of c_s,the apparent diffusion coefficients can be measured rapidly and relatively accurately by the AgNO_3 colorimetric method.
出处 《硅酸盐学报》 EI CAS CSCD 北大核心 2010年第11期2178-2184,共7页 Journal of The Chinese Ceramic Society
关键词 氯离子表观扩散系数 硝酸银显色法 变色深度 变色边界氯离子浓度 混凝土 chloride apparent diffusion coefficient silver nitrate colorimetric method color change depth chloride concentration at color change boundary concrete
  • 相关文献

参考文献22

  • 1何富强,史才军,元强,郑克仁,邹庆焱.硝酸银显色法变色边界处氯离子浓度的影响因素[J].硅酸盐学报,2008,36(7):890-895. 被引量:7
  • 2史才军,元强,邓德华,郑克仁.混凝土中氯离子迁移特征的表征[J].硅酸盐学报,2007,35(4):522-530. 被引量:26
  • 3柴桂红,宁贵霞,赵建昌.氯离子诱发钢筋混凝土桥面板锈蚀开始时间的预测方法探析[J].交通标准化,2006,34(2):38-41. 被引量:1
  • 4元强.水泥基材料中氯离子传输试验方法的基础研究[D]中南大学,中南大学2009.
  • 5余红发.盐湖地区高性能混凝土的耐久性、机理与使用寿命预测方法[D]东南大学,东南大学2004.
  • 6Véronique Baroghel-Bouny,Patrick Belin,Matthias Maultzsch,Dominique Henry.AgNO3 spray tests: advantages, weaknesses, and various applications to quantify chloride ingress into concrete. Part 1: Non-steady-state diffusion tests and exposure to natural conditions[J]. Materials and Structures . 2007 (8)
  • 7Véronique Baroghel-Bouny,Patrick Belin,Matthias Maultzsch,Dominique Henry.AgNO3 spray tests: advantages, weaknesses, and various applications to quantify chloride ingress into concrete. Part 2: Non-steady-state migration tests and chloride diffusion coefficients[J]. Materials and Structures . 2007 (8)
  • 8Accelerated chloride penetration. NORDTEST NT BUILD 443 . 1995
  • 9CHIANG C T,YANG C C.Relation between the diffusion characteristic of concrete from salt ponding test and accelerated chloride migration test. Materials Chemistry and Physics . 2007
  • 10SONG Ha-Won,LEE Chang-Hong,ANN Ki-Yong.Factors influencing chloride transport in concrete structures exposed to marine environments. Cement and Concrete Composites . 2008

二级参考文献70

  • 1中华人民共和国交通部.JTJ270-98水运工程混凝土试验规程[S].北京:人民交通出版社,1998
  • 2SUGIYAMA T,BREMNER T W.Determination of chloride diffusion coefficient and gas permeability of concrete and their relationship[J].Cem Concr Res,1996,26(5):781-790.
  • 3SHARIF A,LOUGHLIN K F,TSUJI Y.Determination of the effective chloride diffusion coefficient in concrete via gas diffusion technique[J].ACI Mater J,1997,94(3):227-233.
  • 4FREEZE R A,CHERRY J A.Groundwater[M].New Jersey:Prentice-Hall Inc,1979.
  • 5PAGE C L,SHORT N R,EL-TARRASAA.A diffusion of chloride ions in hardened cement pastes[J].Cem Concr Res,1981,11 (3):395-406.
  • 6AEC LABORATORY.Concrete testing,hardened concrete.chloride pene tration,APM 302,2nd ed[S].Vedbek,Denmark:AEC Laboratory,1991.
  • 7NORDTEST NT BUILD 443.Accelerated chloride penetration[S].Finland:Nordtest,1995.
  • 8AASHTO T259 (T259-80).Standard method of test for resistance of concrete to chloride ion penetration[S].Washington D C,USA:American Association of State Highway and Transportation Officials,1980.
  • 9SHANE J D,ALDEA,BOUXSEIN N F,et al.Microstructural and pore solution changes induced by rapid chloride permeability test measured by impedance spectroscopy[J].Concr Sci Eng,1999,1(2):1 110-1 119.
  • 10JULIO-BETANCOURT G A,HOOTON R D.Study of the Joule effect on rapid chloride permeability values and evaluation of related electrical properties of concretes[J].Cem Concr Res,2004,34(6):1007-1015.

共引文献29

同被引文献39

  • 1胡蝶,麻海燕,余红发,曹文涛,翁智财.矿物掺合料对混凝土氯离子结合能力的影响(英文)[J].硅酸盐学报,2009,37(1):129-134. 被引量:31
  • 2姬永生,袁迎曙.干湿循环作用下氯离子在混凝土中的侵蚀过程分析[J].工业建筑,2006,36(12):16-19. 被引量:81
  • 3LONG A E, HENDERSON G D, MONTGOMERY F R. Why assess the properties of near-surface concrete [ J ]. Construction and Building Materials, 2001, 15 ( 1 ) : 65- 79.
  • 4MCARTER W, CHRISP T, STARRS G, et al. Field monitoring of electrical conductivity of cover-zone con- crete[ J]. Cement and Concrete Composites, 2005, 27 (8) :809-817.
  • 5MEIRA G, ANDRADE C, ALONSO C, et al. Durability of concrete structures in marine atmosphere zones-the use of chloride deposition rate on the wet candle as an envi- ronmental indicator [ J ]. Cement and Concrete Compos- ites, 2010, 32 (3) :427-435.
  • 6HONG K, HOOTON R. Effects of cyclic chloride expo- sure on penetration of concrete cover [ J ]. Cement and Concrete Research, 1999, 29(6) :1379-1386.
  • 7ANDRADE C. Calculation of chloride diffusion coeffi- cients in concrete from ionic migration measurements [ J ]. Cement and Concrete Research, 1993, 23 (3) :724-742.
  • 8GUSTAVO S D, SILVIA B F. Development of an em- beddable sensor to monitor the corrosion process of new and existing reinforced concrete structures [ J ]. Construc- tion and Building Materials, 2009, 23 ( 8 ) :2746-2751.
  • 9TANG L. Electrically accelerated methods for determining chloride diffusivity in concrete-current development [ J ].Magazine of Concrete Research, 1996, 48 (2) : 173-179.
  • 10DESOUZA S J, HOOTON RD, BICKLEY J. A field test for evaluating high performance concrete cover quali- ty[ J]. Canadian Journal of Civil Engineering, 1998, 25 (3) :551-556.