摘要 目的探讨留置针限速技术在儿童CT增强检查中的优势。方法利用留置针限速技术对431例患儿行腹部CT增强检查。记录全部样本的年龄、体质量、对比剂剂量、注射速率、注射时间和动脉期腹主动脉密度,以及灼热感、呕吐、荨麻疹、过敏反应及对比剂外渗等对比剂不良反应的发生率,进行统计学分析。结果 321例(74.48%)患儿接受手背静脉穿刺,274例(63.57%)使用24G留置针穿刺。平均对比剂注射速率(1.44±0.50)ml/s。仅1例患儿发生对比剂外渗现象,外渗率为0.23%。结论留置针限速技术提高了高压注射器对比剂注射方案在儿童CT增强检查中的安全性,降低了对比剂外渗的发生率,并且动脉期靶血管增强效果可达到诊断要求。 Objective To investigate the advantage of angiocatheter rate limiting technology in contrast-enhanced CT in children.Methods Totally 431 children underwent contrast-enhanced CT examination with angiocatheter rate limiting technology.Age,weight,dosage of contrast medium,injection rate,injection time and the density of abdominal aorta in arterial phase of all the patients were recorded,as well as the rate of sensation of warmth,vomiting,hives,anaphylaxis,contrast medium extravasation and other side effects,and statistic analysis was progressed.Results Venepuncture via vein of dorsum manus was performed in 321 patients(74.48%),in 274 patients(63.57%)with 24G angiocatheter paracentesis.The average injection rate of contrast medium was(1.44±0.50)ml/s.There was only 1 Contrast medium extravasation occurred in only 1 patient(0.23%).Conclusion Angiocatheter rate limiting technology can improve the security of contrast medium injection program used high pressure injection unit in contrast-enhanced CT in children,decrease the incidence rate of contrast medium extravasation,and the enhanced effect of target vessel in arterial phase can satisfy the requirement of diagnosis.
出处 《中国医学影像技术》 CSCD 北大核心 2010年第11期2188-2190,共3页 Chinese Journal of Medical Imaging Technology
关键词 留置针 注射速率 体层摄影术 X线计算机 儿童 Angiocatheter Injection rate Tomography X-ray computed Child
  • 相关文献

参考文献12

  • 1Nakagawa M,Hara M,Shibamoto Y.A prospective study to evaluate the depictability of the hepatic veins on abdominal contrast-enhanced CT in small children.Pediatr Radiol,2009,39(9):933-937.
  • 2Frush DP.Pediatric abdominal CT angiography.Pediatr Radiol,2008,38(Suppl 2):S259-S266.
  • 3Siegel MJ,Babyn PS,Lee EY.Practical CT Techniques//Pediatric body CT.2nd ed.Philadelphia:Lippincott Williams & Wilkins,2008:2-5.
  • 4Chan FP,Rubin GD.MDCT angiography of pediatric vascular diseases of the abdomen,pelvis,and extremities.Pediatr Radiol,2005,35(1):40-53.
  • 5Amaral JG,Traubici J,BenDavid G,et al.Safety of power injector use in children as measured by incidence of extravasation.AJR Am J Roentgenol,2006,187(2):580-583.
  • 6牛凤艳.静脉套管针配合高压注射器在儿童螺旋CT增强扫描中的应用[J].天津护理,2008,16(2):66-67. 被引量:4
  • 7周少萍,李扬彬,谭理连,江金带,梁彤杰,李树欣.静脉套管针在多层螺旋CT增强扫描的应用[J].实用医学杂志,2005,21(21):2450-2450. 被引量:4
  • 8Bellin MF,Jakobsen JA,Tomassin I,et al.Contrast medium extravasation injury:guidelines for prevention and management.Eur Radiol,2002,12(11):2807-2812.
  • 9Cochran ST,Bomyea K,Kahn M.Treatment of iodinated contrast material extravasation with hyaluronidase.Acad Radiol,2002,9(Suppl 2):S544-S546.
  • 10Wang CL,Cohan RH,Ellis JH,et al.Frequency,management,and outcome of extravasation of nonionic iodinated contrast medium in 69 657 intravenous injections.Radiology,2007,243(1):80-87.

二级参考文献6

共引文献31

同被引文献36

引证文献4

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部