期刊文献+

非破坏性检测地下LNAPL污染技术研究 被引量:1

Non-destructive testing of underground LNAPL pollution
下载PDF
导出
摘要 采用非破坏性透地雷达,对台湾嘉义市水上乡地下污染情况施测,参考实地钻探报告,对污染范围进行描绘,经比对施测结果与钻探报告,透地雷达检测比水轻非水相液体(LNAPL)污染结果准确,污染范围判定吻合。 Non-destructive ground-penetrating radar(GPR) was used for detecting underground pollution in Shueishang Township,Chaiyi County of Taiwan.By referring to on-site drilling report,the scope of pollution was determined.Comparing the GRP results with the drilling report,it is found that GPR is accurate in determining the scope of pollution of lighter than water non-aqueous phase liquids(LNAPL).
出处 《武汉科技大学学报》 CAS 2010年第6期646-651,共6页 Journal of Wuhan University of Science and Technology
关键词 透地雷达 比水轻非水相液体 非破坏检测 GPR LNAPL non-destructive testing
  • 相关文献

参考文献11

  • 1Brewster M L,Annan A P.Ground-penetrating radar monitoring of a controlled DNAPL release:200 MHz radar[J].Geophysics,1994,59(8):1 211-1 221.
  • 2Cassidy N J.GPR signal dispersion and attenuation characteristics of LNAPL hydrocarbon contamina -tion[C]∥11th International Conference on Ground Penetrating Radar,Columbus Ohio,2006.
  • 3Marcak H,Golebiowski T.Analysis of GPR trace attributes and spectrum for LNAPL contaminated ground[C] ∥11th International Conference on Ground Penetrating Radar,Columbus Ohio,2006.
  • 4Ajo-Franklin J B,Geller J T,Harris J M.A survey of the geophysical properties of chlorinated DNAPLs[J].Journal of Applied Geophysics,2006,59:177-189.
  • 5Hwang Y K,Endres A L,Piggott S D,et al.Long-term GPR monitoring of a small volume chlorinated solvent release[C]∥11th International Conference on Ground Penetrating Radar,Columbus 2006.
  • 6Francisca F M,Rinaldi V A.Complex dielectric permittivity of soil-organic mixtures (20MHz-1.3GHz)[J].Journal of Environmental Engineering,2003,129(4):347-357.
  • 7De Castro D L,Raimundo Mariano Gomes Castelo Branco.4-D ground penetrating radar monitoring of a hydrocarbon leakage site in Fortaleza (Brazil) during its remediation process:a case history[J].Journal of Applied Geophysics,2003,54:127-144.
  • 8Atekwana E A,Sauck W A,Werkema D D Jr.Investigations of geoelectrical signatures at a hydrocarbon contaminated site[J].Journal of Applied Geophysics,2000,44:167-180.
  • 9Porsani J L,Filho W M,Elis V R,et al.The use of GPR and VES in delineating a contamination plume in a landfill site:a case study in SE Brazil[J].Journal of Applied Geophysics,2004,55:199-209.
  • 10Sauck W A.A model for the resistivity structure of LNAPL plumes and their environs in sandy sediments[J].Journal of Applied Geophysics,2000,44:151-165.

同被引文献8

引证文献1

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部