摘要
使用流动注射进样、多色仪分光、CCD阵列探测器以及微机处理机等,建立了用于多组分同时测定的流动注射-CCD阵列探测器联用分光光度装置。完成以meso-四(4-三甲铵苯基)卟啉为显色剂时铅和镉的同时测量,铅的检出限为0.014μg/mL,镉为0.015μg/mL。
A new kind of spectrophotometric instrument combined with a flow injection device,a prism spectrography,a CCD diode array detection system and a popular microcomputer was established for multi components simultaneous determination.The measurements of lead and cadmuium with meso tetra(4 trimethylammoniumphenyl)porphine were completed with the instrument.The detection limit was 0 014 μg/mL for Pb(Ⅱ) and 0 015 μg/mL for Cd(Ⅱ).The sampling rate was 60 samples/h.
出处
《光谱学与光谱分析》
SCIE
EI
CAS
CSCD
北大核心
1999年第2期212-214,共3页
Spectroscopy and Spectral Analysis
基金
国家自然科学基金