MIC-120拱板的局部失稳试验及研究 被引量:8

TESTS AND RESEARCH ON THE PARTIAL COLLAPSE OFMIC-120 ARC-SHELL ROOF
下载PDF
导出
摘要 为揭示MIC-120彩板波纹拱壳结构的破坏机理,对其进行现场足尺寸试验。通过对8组不同跨度、不同板厚的彩板拱壳进行分级加载,观测其极限承载能力、变形特点以及破坏形式。试验结果表明:影响彩板拱壳极限承载能力的关键是跨度,拱壳的主要破坏形式是腹板局部受压失稳。 An experimental investigation is presented for the arc-shell roof structure with thin-walled corrugated steel section, and a technical evaluation to MIC-120 section in its span range, failure form and deformation behavior is given. The test carried out includes totally 8 full size specimens, which were loaded to collapse under half or full span uniformly distributed loads. It is found that local instability of web of this type of structure is a main reason to cause failure, and that its span should be limited in application.
出处 《工业建筑》 CSCD 北大核心 1999年第5期25-28,共4页 Industrial Construction
关键词 拱板 腹板局部受压 失稳破坏 屋顶 拱壳 MIC-120 section local buckling of wed local in stability