期刊文献+

尿沉渣UF-100检查中鉴别女性尿路感染与尿液污染指标参数的探讨 被引量:9

UF-100 examination of urinary sediment identify urinary tract infections and urinary contaminations with female patients
下载PDF
导出
摘要 目的通过对临床尿路感染组和尿液标本污染组患者尿沉渣和干化学结果对比分析,寻找鉴别尿常规标本是尿路感染或者白带污染的指标参数。方法用受试者工作特征曲线(receiver operating characteristic curve,ROC)分别对尿沉渣结果中白细胞(WBC)、上皮细胞数(EC)、上皮细胞/白细胞比值(E/W)进行评价并计算曲线下面积。结果 WBC、EC、E/W的ROC曲线下面积分别为0.209,0.746,0.976,E/W比值的曲线下面积最大,其最优截断点约为0.22,诊断的灵敏度为0.926,特异度为0.934。结论 EC和E/W可以作为鉴别感染组和污染组的临床检验指标参数,E/W比值对尿液标本污染的诊断价值最高,其最优截断点为0.22。 Objective To looking for indicators of identify urinary tract infection and urinary contamination with UF-100 examination of urinary sediment and dry chemical group.Methods the results of white blood cell count(WBC),epithelial cells(EC),epithelial cells white blood cell ratio(E/ W)were analysis and calculated the area under the receiver operating characteristic curve(ROC).Results WBC,EC,E/W in the area under the ROC curve were 0.209,0.746,0.976.E/W ratio have the largest area under the curve.The optimal truncation point is about 0.22 with the diagnostic sensitivity is 0.926 and specificity 0.934.Conclusion EC and E/W can be used as identification of infection and contamination,E/W ratio have the largest diagnostic value of urine contamination.The optimal cut point is 0.22.
出处 《中国实验诊断学》 北大核心 2011年第1期131-133,共3页 Chinese Journal of Laboratory Diagnosis
基金 山东省科技厅攻关计划资助项目(2007GG30002028) 山东省卫生厅青年基金资助项目(2007QZ011)
关键词 尿沉渣分析 尿液污染 尿分析前质控. Urine analysis urine contamination urine quality control prior to analysis
  • 相关文献

参考文献9

二级参考文献10

  • 1金大鸣.UF-100型尿沉渣全自动检测仪评价[J].中华检验医学杂志,1998,22(3):61-62. 被引量:145
  • 2Zahur Z, Sylvie R, Jan V. Unsatisfacrory performance of flow cytometer UF-100 and urine strips in predicting cutcome of urine cultures[J]. Journal of Clinical Microbiology,2001,39:4169-4171.
  • 3Ben-Ezra J, Bork L, McPherson R. Evaluation of the sysmex UF-100 automated urinalysis analyzer[J]. Clin Chem,1998,44:92-95.
  • 4Fenili D, Pirovano B. The automation of sediment urinalysis using a new urine flow cytometer(UF-100)[J]. Clin Chem Lab Med,1998,36:909-917.
  • 5Kouri TT, Kahkonen U, Malmaniemi K, et al. Evaluation of sysmex UF-100 automated urinalysis analyzer versus chamber counting of supravitally stained specimens and conventional bacterial cultures[J]. Am J Clin Pathol,1999,112:25-35.
  • 6Okada H, Sakai Y, Miyazaki S, et al. Detection of significant bacteriuria by automated urinalysis using flow cytometry[J]. J Clin Microbiol,2000,38:2870-2872.
  • 7Kurt HP,Sieghard CK. Automation of urine sediment examination:a comparison of the sysmex UF-100 automated flow cytometer with routine manual diagnosis (microscopy, test strips and bacterial culture) [J]. Clin Chem Lab Med, 1999,37(7) :753-764.
  • 8金丕焕,曹素华.医用统计方法[M].第2版.上海:复旦大学出版社,2006:424-426.
  • 9胡晓波,熊立凡.全自动尿有形成分分析仪及其临床应用[J].现代医学仪器与应用,1998,10(1):9-11. 被引量:8
  • 10罗效梅,蔡友贤.尿液放置时间对有形成份检查的影响[J].陕西医学检验,1998,13(1):59-59. 被引量:22

共引文献271

同被引文献81

二级引证文献47

相关作者

内容加载中请稍等...