摘要
A transformer type iron core snubber, as a protective device against the stray capacitance during the breakdown in EAST, is analyzed in detail. Three kinds of topology are presented. Then with the analysis for equivalent circuit, the ranges of three key parameters, i.e., secondary side resistance, leakage inductance and snubber inductance, are determined. By con- sidering the saturation of the magnetic material, a design principle is Mso presented. A nearly 1:10 core snubber is tested. It is proved that a high permeability core with secondary resistor can restrain the discharge current effectively.
A transformer type iron core snubber, as a protective device against the stray capacitance during the breakdown in EAST, is analyzed in detail. Three kinds of topology are presented. Then with the analysis for equivalent circuit, the ranges of three key parameters, i.e., secondary side resistance, leakage inductance and snubber inductance, are determined. By con- sidering the saturation of the magnetic material, a design principle is Mso presented. A nearly 1:10 core snubber is tested. It is proved that a high permeability core with secondary resistor can restrain the discharge current effectively.
基金
supported in part by Auxiliary Heating Project of EAST upgrade
in part by Ph. D foundation of State Education Ministry of China(No. 20060248012)