期刊文献+

模拟动力学方法应用于调强放射治疗的研究 被引量:5

The study on an intensity modulated radiotherapy method-the simulated dynamics algorithm
原文传递
导出
摘要 通过建立调强放射治疗计划中的笔束强度和模拟动力学系统中的粒子位置之间的联系,模拟动力学方法可以应用于解决调强放射治疗中的优化问题.本文研究了模拟动力学方法在肿瘤的临床调强放射治疗中的应用.研究表明,在引入软约束、硬约束和剂量体积约束等约束条件后,模拟动力学方法可以满足临床的调强放射治疗计划的要求. By introducing the analogous relationship between the pencil beam intensity in intensity modulated radiotherapy and the atomic position in classical molecular dynamics system, the simulated dynamics algorithm can be used to deal with optimization problem occurring in intensity modulated radiothera- py. A study has been done by applying the simulated dynamics algorithm to several clinical intensity modulates radiotherapy cases. The results show that the simulated dynamics method can satisfy the clinical requirements by additionally employing the soft, hard and dose volume constraints.
出处 《四川大学学报(自然科学版)》 CAS CSCD 北大核心 2011年第1期109-115,共7页 Journal of Sichuan University(Natural Science Edition)
基金 国家自然科学基金重点项目(10335050) 国家自然科学基金面上项目(10475059)
关键词 模拟动力学 调强放射治疗 适形放射治疗 simulated dynamics algorithm, intensity modulated radiotherapy, conform radiotherapy
  • 相关文献

参考文献4

二级参考文献33

  • 1[3]Zhu T C,Das I J,Bjrngard B E.Characteristics of bremsstrahlung in electron beams[J].Med Phys,2001,28(7):1352.
  • 2[4]International Commission on Radiation Units and Measurements.Determination of absorbed dose in a patient irradiated by beams of X or gamma rays in radiotherapy procedures[R].Report 24.Maryland:ICRU,1976.
  • 3[5]Olofsson L,Karlsson M G,Karlsson M.Effects on electron beam penumbra using the photon MLC to reduce bremsstrahlung leakage for an add-on electron MLC[J].Phys Med Biol,2005,50(6):1191.
  • 4[6]Sorcini B B,Hydynmaa S,Brahme A.The role of phantom and treatment head generated bremsstrahlung in high-energy electron beam dosimetry[J].Phys Med Biol,1996,41(12):2657.
  • 5[7]Sorcini B B,Hydynmaa S,Brahme A.Quantification of mean energy and photon contamination for accurate dosimetry of high-energy electron beams[J].Phys Med Biol,1997,42(10):1849.
  • 6[8]Tabata T,Andreo P,Shinoda K,et al.Energy deposition through radiative processes in absorbers irradiated by electron beams[J].Nuclear Instruments and Methods in Physics Research B,1994,93:447.
  • 7Burger H. Development of a low cost PC- based digitally reconstructed radiograph system[J]. XIIth ICCR May, 1997.295 - 287.
  • 8Tiede U, Heinz K, et al. Investigation of medical 3D-rendering algorithms[J]. IEEE Computer Graphics & Application, 1990,10(2) : 41 - 53.
  • 9Robb A, Barillot C. Interactive Display and Analysis of 3D medical images[J]. IEEE Trans. On Medical Imaging, 1989, 8(3) :217 - 226.
  • 10谢逢,罗立民,田雪芹,胡刚.基于知识的人脑三维医学图象自动分析显示系统[J].自动化学报,1997,23(4):496-501. 被引量:3

共引文献6

同被引文献8

引证文献5

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部