一种测量多相流流型的ECT图像重建算法 被引量:4

An Image Reconstruction Algorithm to Testing Flow Patterns of Multiphase Flow for Electrical Capacitance Tomography
原文传递
导出
摘要 提出了一种新的电容层析成像图像重建算法-IMNSNOF算法。该算法在分析极小范数解的基础之上针对ECT逆问题的特点对其进行改进,并利用奇异值分解定理证明这种改进的数值稳定作用。在此基础上建立新的目标泛函,并在求解该泛函的过程中采用正则技巧对其进行改进确保数值解的稳定性。利用非闭合电极ECT传感器实测了多相流沿流向的流型,两种流型图像重建结果显示,IMNSNOF算法图像重建质量高于LBP算法、投影Landweber迭代法及标准的Tikhonov正则法。 A novel image reconstruction algorithm for Electrical Capacitance Tomography(ECT) is presented.According to the ill posed characteristics of ECT inverse problem the minimum norm solution was improved on the basis of analyzing the algorithm,and the stabilization of the numerical solution was proved via singular value decomposition principle.In addition,a new objective functional was established;in the process of solving the functional regularization technique was vised to ensure the stabilization of numerical solution.The flow patterns of multiphase flow were tested using unclosed electrode ECT sensor.The image reconstruction results of two flow patterns indicated the quality of the reconstructed image using the improved algorithm is better than other image reconstruction algorithms such as LBP,projective Landweber iteration algorithm and standard Tikhonov regularization.
出处 《工程热物理学报》 EI CAS CSCD 北大核心 2011年第4期602-604,共3页 Journal of Engineering Thermophysics
基金 国家自然科学基金资助项目(No.50736002)
关键词 多相流流型 电容层析成像 传感器 图像重建算法 flow patterns of multiphase flow Electrical Capacitance Tomography(ECT) sensor image reconstruction algorith
  • 相关文献

参考文献5

  • 1LIU S, YANG W Q, WANG H, et al. Investigation of Square Fluidized Beds Using Capacitance Tomography: Preliminary Results [J]. Measurement Science and Technology, 2001, 12(8): 1120-1125.
  • 2刘靖,刘石,姜凡,雷兢,孙猛.非闭合电极电容层析成像传感器的研制[J].工程热物理学报,2008,29(10):1695-1697. 被引量:2
  • 3Jorge N, Stephen J. Numerical Optimizatation [M]. Beijing: Science Press, 2005:314-571.
  • 4Brani Vidakovic. Statistical Modelling by Wavelets [M]. New York: John Wiley &: Sons, 1999:118-119.
  • 5Acar R, Vogel C R. Analysis of Bounded Variation Penalty Methods for Ⅲ Posed Problem [J]. Inverse Problem, 1994, 10:1217-1229.

二级参考文献5

  • 1York T. Status of Electrical Tomography in Industrial Applications. Journal of Electronic Imaging, 2001, 10(3): 608-619
  • 2Liu S, Yang W Q, Wang H, et al. Investigation of Square Fluidized Beds Using Capacitance Tomography: Preliminary Results. Measurement Science and Technology, 2001, 12(8): 1120-1125
  • 3W Q Yang, W F Conway. Measurement of Sensitivity Distributions of Capacitance Tomography Sensors. Review of Science Instruments, 1998, 69(1): 233-236
  • 4C G Xie, S M Huang, B S Hoyle. Electrical Capacitance Tomography for Flow Imaging: System Model for Development of Image Reconstruction Algorithms and Design of Primary Sensors. IEE Proceedings-G, 1992, 139(1): 89-98
  • 5王化祥,张立峰,朱学明.电容层析成像系统阵列电极的优化设计[J].天津大学学报(自然科学与工程技术版),2003,36(3):307-310. 被引量:30

共引文献1

同被引文献38

引证文献4

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部