分析了电站送风机轴承磨损,腐蚀直至损坏的原因,即由于安装质量以及密封失效等造成的振动加剧以及润滑失效等因素综合作用而导致轴承损坏.文中提出了预防及维护的措施以及所取得的良好效果.
The failure analyses of fan blower bearing in power plant are carried out. It is the mutiphasic cases caused the failure of bearing, such as the quality of installation and the bad seal, then the high vibration and the failure of ubrication occured. In this article, the improvement methods of prevention and maintenance and the excellent effects are then presented.
出处
《节能技术》
CAS
1999年第5期43-43,45,共2页
Energy Conservation Technology
关键词
磨损
腐蚀
维护
发电站
锅炉
fan bearing,wear,corrosion,prevention and maintenance