分析了耒阳电厂670 t/h 燃用当地低挥发分无烟煤锅炉燃烧效率低的原因,提出并实施了一系列技术攻关措施,逐步提高了锅炉燃烧效率,为我国电站锅炉燃烧无烟煤提供了经验。
The causes for low combustion efficiency of low volatile matter anthracite fired 670 t/h boilers in Leiyang Power Plant were analyzed,and a series of technical measures were put forward and into practice,thus the combustion efficiency of boiler was improved gradually,providing experiences for anthracite fired utility boilers in China