基于SHPB试验的纤维增强陶瓷材料抗爆能力的研究 被引量:2

Study on Anti-burst Performance of Fiber Reinforced Porcelain Based on Split Hopkinson Pressure Bar Test
原文传递
导出
摘要 为分析纤维添加量对陶瓷材料抗爆性能的影响,应用霍普金森压杆(SHPB)试验对3组不同纤维含量的陶瓷试样进行了冲击试验,得到了断裂强度及应变率曲线。试验结果表明:添加5%纤维的增韧陶瓷具有更高的断裂强度和更低的应变率,该成分对于改善陶瓷的动态冲击强度和抗爆性能效果最好。 Split hopkinson pressure bar(SHPB)was used to study the effect of three different fiber volume fractions to anti-burst performance of composite porcelain.The stress and strain rate curves were obtained.The test results show that the reinforced porcelain with adding 5% fiber addition has higher fracture stress and lower strain rate,and best anti-burst performance.This composition has the best effect for improving the dynamic impact strength and ceramic anti-explosion performance of the porcelain.
机构地区 ABB中国研究中心
出处 《电瓷避雷器》 CAS 北大核心 2011年第2期7-9,15,共4页 Insulators and Surge Arresters
关键词 纤维增强陶瓷 SHPB 抗爆性能 断裂应力 应变率 fiber reinforced porcelain SHPB anti-burst performance fracture stress strain rate
  • 相关文献

参考文献3

二级参考文献103

共引文献42

同被引文献45

  • 1谢建国,钱端芬,徐协文,敖聪聪,文作运,梁丽霞.超高强度硅酸盐水泥胶合剂[J].电瓷避雷器,1996(4):21-28. 被引量:6
  • 2BENSTED J, BARNES P. Structure and performance of ce-ments[M].北京:化学工业出版社.2007.
  • 3刘汗贤,邓玉珠.掺硅灰高强混凝土的应用[J].电瓷避雷器,1989(2):18-23,32.
  • 4李玉书,吴落义,李瑛.电瓷工艺与技术[M].北京:化学工艺出版社.2009.
  • 5SELTZER-GRANT M, MACKINLAY R, RENFORTH L. New techniques for on-line partial discharge testing of solid-insulated outdoor MV and HV plant[C]//UPEC 42nd International Universities Power Engineering Conference. [S.l.]:IEEE, 2007:486-489.
  • 6PENG Xiaosheng, L! Zhaohui, ZHOU Chengke. Asuc- cessful on-site PD testing experience of 11 kV EPR cable in- sulation systems [C]// 2010 International Conference on Power System Technology. Hangzhou: IEEE,2010:1-5.
  • 7MING Yao. The application of temporary earth voltage (TEV) measurement in the online monitoring of the partial discharge of HV switch cabinet [C]//2010 China Interna- tional Conference on Electricity Distribution. Nanjing: CI- CED, 2010:1-6.
  • 8JENNINGS E,COLLINSONA.A partial discharge monitor for the measurement of partial discharges in a high voltage plant by the transient earth voltage technique[C]//1993 In- ternational Conference on Partial Discharge. Canterbury: IEEE, 1993:30-91.
  • 9DAVIES N, YUAN Tian,TANG J C Y. Non-intrusive partial discharge measurements on high voltage switchgear [C]//2008 International Conference on Condition Monitor- ing and Diagnosis. Beijing: CMD,2008:385-388.
  • 10GOLDTHORPE S,FERRIS R,HODGSON S.Use of web based partial discharge monitoring to extend asset life[C]// 2009 International Conference on Electricity Distribution. Prague, Czech Repubhc: CIRED, 2009:1-3.

引证文献2

二级引证文献54

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部