期刊文献+

温度对超声波检测缺陷定位定量的影响 被引量:10

Temperature Effect on Quantitative Ultrasonic Testing of Defects
下载PDF
导出
摘要 外界温度变化影响超声波检测缺陷的定位与定量。结合海洋工程生产实践,自行设计了恒温实验箱,以模拟工程现场环境温度。在-20~120℃范围内,开展温度对超声波检测缺陷定量定位影响的研究。得到了超声波横波声速变化对于深度测量影响的关系式,用以修正不同温度下的缺陷深度的定位,对超声波检测的准确定位和定量有一定作用。 The change of environment temperature often affects defect location and ration of ultrasonic testing. Combining with ocean engineering practice,an invariable temperature experiment chest which simulates engineering field environment temperature is designed to investigate the temperature effect on defect location and ration of ultrasonic testing in the range of -20~100℃.The relational expression for the change of transversal wave velocity on depth measurement was acquired and used to modify defect location in different temperature.This research performs direction function for ultrasonic testing.
出处 《无损检测》 2011年第4期26-29,32,共5页 Nondestructive Testing
关键词 超声波检测 温度 缺陷 定位 定量 Ultrasonic testing Temperature Orientation Quantitative
  • 相关文献

参考文献4

二级参考文献20

  • 1谢宝琛,王兆节,徐正江.斜探头K值随环境温度的变化[J].无损检测,1989,11(8):226-228. 被引量:7
  • 2高温横波探伤中温度梯度的影响[J].无损探伤,1986,(3).
  • 3RW尼柯尔斯.压力容器技术进展-2探伤与检验[M].北京:机械工业出版社,1994..
  • 4.超声波探伤[M].北京:水利电力工业出版社,1985..
  • 5.美国无损检测手册-超声卷[M].北京:北京图书出版公司,1996..
  • 6章燕谋.锅炉与压力容器用钢[M].西安:交通大学出版社,1996..
  • 7J克劳特克洛默 H·克劳特克洛默著 李靖等译.超声检测技术[M].广东:广东科技出版社,1984..
  • 8Lynnworth, L.,Use of Ultrasonics for High Temperature Measurments Materids Evaluation[J],1969,27(3):60~66.
  • 9Silber, F., and O.Ganglbauer. Ultrasonic Testing of Hot welds, NDT International[J],1970,3(6):471~476.
  • 10Canella, G. and F. Monti,Ultrasonic Inspection of Hot Thick Steel Products NDT International[J], 1980,13(61):10~14.