基于脲酶催化和酸碱指示剂变色原理的高脲乳快速检测方法的建立 被引量:2

Rapid Detection Method for High-Urea Milk Based on Urease Catalysis
下载PDF
导出
摘要 针对市场上存在的高脲乳(掺假和病理性)问题,建立区别于正常生理浓度范围的快速检测方法。检测方法依据尿素被酶解导致的pH值升高幅度与其浓度呈正相关这一机理,对牛乳起始pH值进行优化调整为6.8时,选择溴百里酚蓝作为指示剂,可以使乳脲含量达40mg/100mL生理上限卡切值以上时变色,从而区别检出高脲问题乳。研究表明,依此组装的高脲乳检测试剂盒,可用于生产实践。 The objective of this study is to establish a rapid detection method for milk with urea content exceeding physiological range.Based on the fact that pH increase could result from urea enzymolysis positively correlated with urea concentration.Bromothymol blue was chosen as the acid-base indicator to determine high-urea milk.The indicator can develop color from yellow-brown to green-blue when urea content was higher than 40 mg/100 mL.On the basis of our present study,the developed reagent kit for the determination of high-urea milk is useful for practical application.
出处 《食品科学》 EI CAS CSCD 北大核心 2011年第10期222-226,共5页 Food Science
关键词 尿素掺假乳 病理性高脲乳 检测试纸 检测试剂盒 脲酶 乳脲氮 adulterated milk pathological high-urea milk test paper milk-urea reagent kit urease milk urea nitrogen
  • 相关文献

参考文献17

  • 1HOJMAN D, KROLL O, ADIN G, et al. Relationships between milk urea and production, nutrition and fertility traits in israeli dairy herds[J]. J Dairy Sci, 2004, 87(4): 1001-1011.
  • 2HOJMAN D, GIPS M, EZRA E. Association between live body weight and milk urea concentration in holstein cows[J]. J Dairy Sci, 2005, 88 (2): 580-584.
  • 3SHARMA R, RAJPUT Y S, KAUR S, et al, A method for estimation of urea using ammonia electrode and its applicability to milk samples[J]. J Dairy Res, 2008, 75(4): 466-470.
  • 4JONKER J S, KOHN R A, ERDMAN R A. Using milk urea nitrogen to predict nitrogen excretion and utilization efficiency in lactating dairy cows[J]. J Dairy Sci, 1998, 81(10): 2682-2692.
  • 5KOHN R. Caution needed when interpreting MUNs[J]. Hoards Dairyman, 2000. 145(2): 58.
  • 6FRANCIS P S, LEWIS S W, LIM K F. Analytical methodology for the determination of urea: current practice and future trends[J]. Trends in analytical chemistry, 2002, 21(5): 389-400.
  • 7SINGH M, VERMA N, GARG A K, et al, Urea biosensors[J]. Sensors and Actuators B, 2008, 134(1): 345-351.
  • 8TRIVEDI U B, LAKSHMINARAYANA D, KOTHARI I L, et al. Potentiometric biosensor for urea determination in milk[J]. Sensors and Actuators B, 2009, 140(1): 260-266.
  • 9徐黎,叶兴乾,沈英,俞海琦.原料乳中尿素掺假快速检测方法的研究[J].中国乳品工业,2004,32(3):34-35. 被引量:9
  • 10柯爱飞,王趁义,牛习,朱利华,罗瑞.脲酶抑制剂的研究现状与展望[J].安徽农业科学,2009,37(23):10883-10884. 被引量:10

二级参考文献34

共引文献17

同被引文献27

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部