1Collange O, Xavier I, Kuntzman H, et al. Flotrac for monitoring arterial pressure and cardiac output during phaeochromocytomasurgery [ J ]. Eur J Anaesthesiol, 2008,25 (9) : 779- 780.
2Manecke G R Jr, Auger W R. Cardiac output determination from the arterial pressure wave: clinical testing of anovel algorith that dose not require calibrationg [ J ]. J Cardiothorac Vasc Anesth, 2007,21( 1 ) :3-7.
3Maus T M, Lee D E. Arterial pressure-based cardiac output assessment[ J ]. J Cardiothorac Vasc Anesth, 2008,22 ( 3 ) : 468-473.
5breukers S R, Sepehrkhouy S, Soiegelenberg S R, et al. Cardiac output meastlred by a new arterial pressure waveform analysis method without calibration compared with thermodilution after cardiac surgery[ J ]. J Cardiothorac Vasc Anesth, 2007,21 (5) :632-635.
6Chakravarthy M, Patil T A, Jayaprakash K. et al. comparison of simultaneous estimation of cardiac output by four techniques in patients undergoing off-pump coronary artery bypass surgery- A prospective observational study[ J ]. Annals of cardiac anesthesia, 2007,10(2):121-126.
7Button D, Werbel L, Reuthebuch O, et al. Clinical evaluatin of the FloTrac/Vigileo TM system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery[ J ]. Br J Anesth, 2007,99 ( 3 ) :329- 336.
8McGee W T, Horswell J L, L Calderon J, et al. Validation of a continous arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial[ J ]. Critical Care, 2007,11(5) :105.
9Biais M, Karine N G, Vincent C, et al. Cardiac output measurement in patients undergoing liver transplantation: pulmonary artery catheter versus uncalibrated arterial pressure waveform analysis [ J ]. Anesth Analg, 2008, 106 (5) : 1480-1486.
10Hofer C K, Senn A, Weibel L, et al. Assessment of stroke volume variation for prediction of fluid responsiveness using the modified FloTrac TM and PiCCO plus TM system [ J ]. Critical Care, 2008,12(3) :82.
二级参考文献4
1BERRIDGE JC,WARRING-DAVIES K,BLAND JM,et al.A new,minimally invasive technique for measuring cardiac index:clinical comparison of continuous cardiac dynamic monitoring and pulmonary artery catheter methods[J].Anaesthesia,2009,64(9):961-967.
2YAMAGISHI A,KUNISAWA T,KUROSAVA A,et al.Utility of SVV(stroke volume variatin) during abdominal aortic surgery.Masui[J] ,2010,59(2):197-201.
3MAYER J,BOLDT J,MENGISTU A,et al.Goal-directed intraoperative therapy based on autocalibrated arterial pressure waveform analysis reduces hospital stay in high-risk surgical patients:a randomized,controlled trial[J].Crit Care,2010,14(10):R18.
4BUTTON D,WEIBEL1 L,REUTHEBUCH OM.et al.Clinical evaluation of the FloTrac/VigileoTM system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery[J].British Journal of Anaesthesia,2007,99(3):329-336.
8Button D, Weibel L, Reuthebach O M, et al. Clinical e- valuation of the FloTrac/Flotrac/VigileoTM system and two established continuous cardiac output monitoring devices in patients undergoing cardiac surgery [ J ]. Br J Anaesth, 2007,99 ( 3 ) : 329-336.
9Biancofiore G, Critchley L A, Lee A, et al. Evaluation of an uncalibrated arterial pulse contour cardiac output moni- toring system in cirrhotic patients undergoing liver surgery [ J ]. Br J Anaesth, 2009,102 ( 1 ) :47-54.
10Sakka S G, Kozieras J, Thuemer O, et al. Measurement of cardiac output: a comparison between transpulmonary ther- modilution and uncalibrated pulse contour analysis [ J ]. Br J Anaesth, 2007,99 ( 3 ) : 337-342.