期刊文献+

补风速度对中庭类建筑机械排烟效果的影响 被引量:13

Effect of make-up air velocity on mechanical smoke exhaust efficiency in buildings with atrium
下载PDF
导出
摘要 通过数值模拟计算,研究了补风速度对排烟效果的影响。结果表明,补风速度为7 m/s时,烟羽流倾斜比较严重;补风速度为5,3 m/s时,烟羽流倾斜程度较小;补风速度为1 m/s时,对烟羽流形状基本没有影响。补风速度为7,5,3 m/s时,烟气层高度下降较快;补风速度为1 m/s时,烟气层高度下降较慢。 Performs a reasearch by numerical simulation.The results show that when the make-up air velocity is 7 m/s,the fire plume is seriously inclined;when the velocity is 5 m/s or 3 m/s,the fire plume is slightly inclined;and the velocity of 1 m/s has little influence on the fire plume;and that for the make-up air velocity of 7 m/s,5 m/s,and 3 m/s,the smoke layer height descends faster;when the make-up air velocity is 1m/s,the smoke layer height descends relatively slower.
出处 《暖通空调》 北大核心 2011年第5期72-74,49,共4页 Heating Ventilating & Air Conditioning
基金 中国人民武装警察部队学院青年教师基金资助项目(编号:WJXY2010-QNJS024)
关键词 中庭 机械排烟 补风速度 数值模拟 atrium mechanical smoke exhaust make-up air velocity numerical simulation
  • 相关文献

参考文献11

  • 1Tanaka T, Yamana T. Smoke control in large scale spaces(part 1) E.I-]. Fire Science and Technology, 1985,5(1) :31-40.
  • 2Milke J A. Smoke management for covered malls and atria[J]. Fire Technology, 1990,26 (3) : 223- 243.
  • 3Milke J A, Mowrer F W. A design algorithm for smoke management systems in atria and covered malls[R]. Maryland: University of Maryland College Park, 1993.
  • 4Hadjisophocleous G V, Lougheed G D. Experimental and numerical study of smoke conditions in an atrium with mechanical exhaust[J]. International Journal on Engineering Per{ormance-Based Fire Codes, 1999, 1 (3):183-187.
  • 5Klote J H. An overview of atrium smoke management [J].Fire Protection Engineering, 2000 (7):24-34.
  • 6Klote, J H. Method of predicting smoke movement in atria with application to smoke management[R]. Gaithersburg, Maryland. National Institute of Standards and Technology, 1994.
  • 7朱鸣.中庭建筑防排烟设计问题探讨[J].消防科学与技术,2000,19(2):24-26. 被引量:8
  • 8李思成,陈颖,陈兴,等.中庭机械排烟不同补风量效果数值模拟[C]//第五届消防性能化与消防工程研讨会.广州,20lO.
  • 9National Fire Protection Association. NFPA92B Guide for smoke management systems in malls, atria, and large areas[S]. Quincy, MA, US: The Standards Counci, 1995.
  • 10中华人民共和国公安部.GB50045-95高层民用建筑设计防火规范(2005年版)[S].北京:中国计划出版社,2005