期刊文献+

Endoscopic removal and trimming of distal self-expandable metallic biliary stents 被引量:1

Endoscopic removal and trimming of distal self-expandable metallic biliary stents
下载PDF
导出
摘要 AIM:To evaluate the efficacy and safety of endoscopic removal and trimming of self-expandable metallic stents(SEMS).METHODS:All SEMS had been placed for distal biliary strictures.Twenty-seven endoscopic procedures were performed in 19 patients in whom SEMS(one uncovered and 18 covered) removal had been attempted,and 8 patients in whom stent trimming using argon plasma coagulation(APC) had been attempted at Tokyo Medical University Hospital.The APC settings were:voltage 60-80 W and gas flow at 1.5 L/min.RESULTS:The mean stent indwelling period for all patients in whom stent removal had been attempted was 113.7 ± 77.6 d(range,8-280 d).Of the 19 patients in whom removal of the SEMS had been attempted,the procedure was successful in 14(73.7%) without procedure-related adverse events.The indwelling period in the stent removable group was shorter than that in the unremovable group(94.9 ± 71.5 d vs 166.2 ± 76.2 d,P = 0.08).Stent trimming was successful for all patients with one minor adverse event consisting of self-limited hemorrhage.Trimming time ranged from 11 to 16 min.CONCLUSION:Although further investigations on larger numbers of cases are necessary to accumulate evidence,the present data suggested that stent removal and stent trimming is feasible and effective for stent-related complications. AIM:To evaluate the efficacy and safety of endoscopic removal and trimming of self-expandable metallic stents(SEMS).METHODS:All SEMS had been placed for distal biliary strictures.Twenty-seven endoscopic procedures were performed in 19 patients in whom SEMS(one uncovered and 18 covered) removal had been attempted,and 8 patients in whom stent trimming using argon plasma coagulation(APC) had been attempted at Tokyo Medical University Hospital.The APC settings were:voltage 60-80 W and gas flow at 1.5 L/min.RESULTS:The mean stent indwelling period for all patients in whom stent removal had been attempted was 113.7 ± 77.6 d(range,8-280 d).Of the 19 patients in whom removal of the SEMS had been attempted,the procedure was successful in 14(73.7%) without procedure-related adverse events.The indwelling period in the stent removable group was shorter than that in the unremovable group(94.9 ± 71.5 d vs 166.2 ± 76.2 d,P = 0.08).Stent trimming was successful for all patients with one minor adverse event consisting of self-limited hemorrhage.Trimming time ranged from 11 to 16 min.CONCLUSION:Although further investigations on larger numbers of cases are necessary to accumulate evidence,the present data suggested that stent removal and stent trimming is feasible and effective for stent-related complications.
出处 《World Journal of Gastroenterology》 SCIE CAS CSCD 2011年第21期2652-2657,共6页 世界胃肠病学杂志(英文版)
关键词 Self-expandable metallic stent Endoscopic biliary stenting Endoscopic stent removal Endoscopic stent trimming 金属支架 修剪时间 内镜 远端 胆道 清除 SEMS 支架拆除
  • 相关文献

参考文献24

  • 1Prat F, Chapat O, Ducot B, Ponchon T, Pelletier G, Fritsch J, Choury AD, Buffet C. A randomized trial of endoscopic drainage methods for inoperable malignant strictures of the common bile duct. Gastrointest Endosc 1998; 47:1-7.
  • 2Isayama H, Komatsu Y, Tsujino T, Sasahira N, Hirano K, Toda N, Nakai Y, Yamamoto N, Tada M, Yoshida H, Shi- ratori Y, Kawabe T, Omata M. A prospective randomised study of "covered" versus "uncovered" diamond stents for the management of distal malignant biliary obstruction. Gut 2004; 53:729-734.
  • 3Roebuck DJ, Stanley P, Katz MD, Parry RL, Haight MA. Gastrointestinal hemorrhage due to duodenal erosion by a biliary wallstent. Cardiovasc Intervent Radiol 1998; 21:63-65.
  • 4Demarquay JF, Dumas R, Peten EP, Rampal P. Argon plasma endoscopic section of biliary metallic prostheses. Endoscopy 2001; 33:289-290.
  • 5Yarze JC, Poulos AM, Fritz HP, Herlihy KJ. Treatment of metallic biliary stent-induced duodenal ulceration using en- doscopic laser therapy. Dig Dis Sci 1997; 42:6-9.
  • 6Bueno JT, Gerdes H, Kurtz RC. Endoscopic management of occluded biliary Wallstents: a cancer center experience. Gas- troin test Endosc 2003; 58:879-884.
  • 7Kahaleh M, Tokar J, Le T, Yeaton P. Removal of self-expand- able metallic Wallstents. Gastrointest Endosc 2004; 60:640-644.
  • 8Familiari P, Bulajic M, Mutignani M, Lee LS, Spera G, Spada C, Tringali A, Costamagna G. Endoscopic removal of malfunc- tioning biliary self-expandable metallic stents. Gastrointest Endosc 2005; 62:903-910.
  • 9Shin HP, Kim MH, Jung SW, Kim JC, Choi EK, Han J, Lee SS, Seo DW, Lee SK. Endoscopic removal of biliary self-expand- able metallic stents: a prospective study. Endoscopy 2006; 38: 1250-1255.
  • 10Vanbiervliet G, Piche T, Caroli-Bosc FX, Dumas R, Peten EP, Huet PM, Tran A, Demarquay JF. Endoscopic argon plasma trinmzing of biliary and gastrointestinal metallic stents. En- doscopy 2005; 37:434-438.

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部