期刊文献+

工频电磁场对变电站工人雄激素水平影响研究 被引量:1

Effects of power frequency electromagnetic field on androgen expression in 500kV substation male workers
原文传递
导出
摘要 目的研究工频电磁场对500 kV变电站工人周围血雄激素水平的影响。方法选择广东省内500 kV变电站310名男性巡检人员作为暴露人群及300名各变电站男性行政管理人员作为对照人群,分别抽取周围血5 ml,用人雄激素酶联免疫吸附法试剂盒进行测定。结果 500 kV变电站工人与对照组2组人群工作场所暴露工频电场(Z=-11.322,P=0.000)、工频磁场(Z=-22.585,P=0.000)差异有统计学意义。经校正后,变电站巡检工人与对照人群血清雄激素水平差异无统计学意义(F=0.003,P=0.958)。结论在长期接触工频电磁场的职业人群中未观察到血清雄激素水平与工频电磁场的相关性。 Objective To investigate the effects of power frequency electromagnetic field on androgen in male workers.Methods 310 male workers and 300 male administrative staff were selected as the exposed and the control group respectively.The levels of serum androgen were determined by ELISA assay.Results The differences of power frequency electric field and power frequency magnetic field between the exposed and the control group were statistically significant(Z=-11.322,P=0.000),(Z=-22.585,P=0.000),respectively.The difference of androgen level was not statistically significant(F=0.003,P=0.958).Conclusion Power frequency electromagnetic field may have no effects on androgen expression in 500 kV substation male workers.
出处 《中国职业医学》 CAS 北大核心 2011年第3期204-206,共3页 China Occupational Medicine
基金 广东省医学科研基金立项课题(A2007059) 广东电网公司立项课题(JA6008017)
关键词 工频电磁场 变电站 雄激素 Power frequency electromagnetic fields Substation Androgen
  • 相关文献

参考文献15

二级参考文献79

共引文献48

同被引文献10

  • 1Coskun O,Comlekci S.Effect of ELF electric field on some onbiochemistry characters in the rat serum[J].Toxicol IndHealth,2011,27(4):329-333.
  • 2Gobba F,Bargellini A,Bravo G,et al.Natural killer cellactivity decreases in workers occupationally exposed toextremely low frequency magnetic fields exceeding 1microT[J].Int J Immunopathol Pharmacol,2009,22(4):1059-1066.
  • 3Cakir DU,Yokus B,Akdag MZ,et al.Alterations ofhematological variations in rats exposed to extremely lowfrequency magnetic fields(50Hz)[J].Arch Med Res,2009,40(5):352-356.
  • 4Ushiyama A,Ohkubo C.Acute effects of low-frequencyelectromagnetic fields on leukocyte-endothelial interactions invivo[J].In Vivo,2004,18(2):125-132.
  • 5Syromiatnikov IuP.State of peripheral blood of technicalpersonnel exposed to constant magnetic fields[J].Med TrProm Ekol,1995(10):11-14.
  • 6Baieth HEA.Physical parameters of blood as a non-newtonianfluid[J].Int J Biomed Sci,2008,4(4):323-329.
  • 7Hashish AH,El-Missiry MA,Abdelkader HI,et al.Assessment of biological changes of continuous whole bodyexposure to static magnetic field and extremely low frequencyelectromagnetic fields in mice[J].Ecotoxicol Environ Saf,2008,71(3):895-902.
  • 8Cicekcibasi AE,Celik I,Salbacak A,et al.Determination ofthe effects of extremely low frequency electromagnetic fields onthe percentages of peripheral blood leukocytes and histology oflymphoid organs of the mouse[J].Saudi Med J,2008,29(1):36-41.
  • 9秦景香,刘武忠,周敏,翁玮,沈富荣,朱骏,郑爱国,符英英.工频电场作业人员神经行为功能和健康状况的研究[J].环境与职业医学,2010,27(10):590-593. 被引量:11
  • 10温翠菊,闫雪华,李丽,黎丽春,张丹英,邹剑明.500kV变电站工人HSP70表达水平研究[J].海南医学,2011,22(13):1-3. 被引量:1

引证文献1

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;