4Cooney WP,Bussey R,Dobyns JH,etal.Difficult wrist fractures.Perilunate fracture-dislocations of the wrist[J].Clin Orthop Relat Res,1987,(214):136-147.
二级参考文献11
1Beharrie AW, Beredjiklian PK, Bozentka DJ. Functional out- comes after open reduction and internal fixation for treatment of displaced distal radius fractures in patients over 60 years of age. J Orthop Trauma, 2004, 18(10) :680 -686.
2Ganland JJ Jr, Werley C. Evaluation of healed Coiles'fractures. J Bone Joint Surg (Am), 1951, 33(33) :895 -907.
3Young BT, Rayan GM. Outcome following nonoperative treatment of displaced distal radius fractrues in low - demand patients older than 60 years. J Hand Surg (Am), 2000, 25(1):19-28.
4Baratz ME, Des Jardins J, Anderson DD, et al. Displaced intra - articular fractures of the distal radius: the effect of fracture displacement on contact stresses in a cadaver model. J Hand Surg (Am), 1996, 21(2) :183 -188.
5Hastings H 2nd, Leibovic SJ. Indications and techniques of open reduction. Internal fixation of distal radius fractures. Orthop Clin North (Am), 1993, 24(2) :309 -326.
6Orbay JL, Fernandez DL. Volar fixed - angle plate fixation for unstable distal radius fractures in the elderly patient. J Hand Surg (Am), 2004, 29(1):96-102.
7Schupp A, Tuttlies C, Mohlig T, et al. Distal radius fractures 2.4 mm locking compression plates. Are they worth the effort? Chirurg, 2003, 74( 11 ) :1009 - 1017.
8Kamath AF, Zurakowski D, Day CS. Low - profile dorsal plating for dorsally angulated distal radius fractures: an outcomes study. J Hand Surg ( Am), 2006, 31 ( 7 ) : 1061 - 1067.
9Duncan SF, Weiland AJ. Minimally invasive reduction and osteosynthesis of articular fractures of the distal radius. Injury, 2001, 32 Suppl 1:14 -24.
10Kreder H J, Hanel DP, Agel J, et al. Indirect reduction and percutaneous fixation versus open reduction and internal fixation for displaced intra - articular fractures of the distal radius: a randomised, controlled trial. J Bone Joint Surg (Br) , 2005, 87 (6) :829 -836.
5Liporace FA, Gupta S, Jeong CK, et al. A biomechamical compari- on of a dorsal 3.5 - nom T - plate and a volur fixedangle plate in a modil of dorsally unstable atistal radius fractures [ ] ] . J, Othop Trauma,2005,19(3) :187 - 191.
6Dienst M, Wozasek GE, Seligsoo D. Dynsmic external fixation for distul radciis frastunes [ J ]. Clin Orthop Relot Res, 1997 ( 338 ) : 160 - 171.
7Brogren E,Petranek M,Atroshi I. Incidence and characteristics of distal radius fractures in a southern Swedish region[J].{H}BMC Musculoskeletal Disorders,2007.48.
8Freeland AE,Luber KT. Biomechanics and biology of plate fixation of distal radius fractures[J].{H}Hand Clinics,2005,(03):329-339.
9Liporace FA,Gupta S,Jeong GK. A biomechanical comparison of a dorsal 3.5-mm T-plate and a volar fixed-angle plate in a model of dorsally unstable distal radius fractures[J].{H}Journal of Orthopaedic Trauma,2005,(03):187-191.
10Dienst M,Wozasek GE,Seligson D. Dynamic external fixation for distal radius fractures[J].{H}Clinical Orthopaedics and Related Research,1997,(338):160-171.