期刊文献+

心率变化对多层螺旋CT冠状动脉成像的影响 被引量:1

心率变化对多层螺旋CT冠状动脉成像的影响
下载PDF
导出
摘要 目的探讨心率变化对多层螺旋CT冠状动脉成像的影响。方法本研究选取在临床上疑似患有冠心病的患者共298例,定位图像确定后进行钙化分析轴位扫描,再进行增强扫描,观察不同心率变化对冠状动脉图像质量的影响。结果 298例患者共显示血管3043支,其中可评估血管占78.77%,不可评估血管占21.23%;可评价血管显示率从组N1至N7逐渐降低,运动伪影百分量从组N1至N7逐渐递增;不同心率组的图像质量比较,差异具有统计学意义(P<0.05)。结论心率变化在最佳重建图像质量获取中是一个不容忽视的因素。 Objective To learn the effluence of coronary angiography on multi-slice spiral CT with the change of heart rate. Methods There are 298 patients doubted with coronary disease in clinic. The fixed images are defined then calcification analysis and axial view scanning,and later strengthen scanning. Observe the effluence on the quality of coronary artery images with different heart rate. Results 298 patients have 3043 obvious blood vessel,including assessable blood vessel(78.77%) and unassessable blood vessel(21.23%) . The display rate of assessable blood vessel reduces from group N1 to N7 and the percent of motion artifact increase from group N1 to N7. The diverse of different heart rate has statistical significance(P0.05) . Conclusion The change of heart rate is a indispensable factor in gaining best quality reconstructed image.
出处 《当代医学》 2011年第19期64-65,共2页 Contemporary Medicine
关键词 心率 多层螺旋 CT 冠状动脉 Heart rate Multi-slice spiral CT Coronary artery
  • 相关文献

参考文献4

二级参考文献16

  • 1陈在熹,高润霖.冠心病[M].北京:人民卫生出版社,2002:145-146.
  • 2Schaller S, Flohr T, KlingenbecK K, et al. Spiral interpolation algorithm for multislice spiral. CT-part I:Theory [J]. IEEE Trans Med Imaging, 2000, 19 (9): 822-834.
  • 3Ohnesorge B, Flohr T, Shallers, et al.The technical bases and uses of multi-slice CT [J]. Radiology, 1999, 39 ( 11 ): 930-931.
  • 4Van Hoe L,Marchal G,Baert AL,et al.Determination of scan delay time in spiral CT-angiography:Utility of a test bolus injection[J].J Comput Assist Tomogr,1995,19:216-220.
  • 5Hong C,Becker C R,Huber A,et al.ECG-gated reconstructed multi-detector row CT coronary angiography:effect of varying trigger delay on image quality[J].Radiology,2001,220 (3):712-717.
  • 6Windecker S,Maier-Rudolph W,Bonzel T,et al.Interventional cardiology in Europe 1995[J].Eur Heart J,1999,20(7):484-495.
  • 7Schroeder S,Kopp A F,Baumbach A,et al.Influence of heart rate on vessel visibility in noninvasive coronary angiography using new multislice computed tomography:experience in 94 patients[J].Clinical Imaging,2002,26 (2):106-111.
  • 8Nieman K,Rensing B J,Van Geuns R J,et al.Non-invasive coronary angiography with multislice spiral computed tomography:impact of heart rate[J].Heart,2002,88 (5):470 -474.
  • 9Martin H K,Hoffmann M D,Heshui Shi M D,et al.Noninvasive coronary angiography with 16-detector row CT:effect of heart rate[J].Radiology,2005,234:98-108.
  • 10唐陶富,李世胜.多层螺旋CT冠脉成像在冠心病诊断中的临床应用进展[J].中国医疗前沿,2009,4(20):14-16. 被引量:16

共引文献76

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部