摘要
珊溪电厂2号水轮发电机组A修中发现定子线棒磨损。通过分析确定了线棒磨损的原因,详细介绍了定子线棒的修复过程、修后试验,提出了相应防范措施。
The abrasion of stator winding bar for No.2 hydro-generator unit is found in the overhaul in Shanxi Hydropower Plant.The causes are identified through the analysis.The repair process and test after repair of stator winding bar are described in detail.And the relevant protective measures are put forward.
出处
《浙江电力》
2011年第6期42-45,共4页
Zhejiang Electric Power
关键词
水轮发电机
定子线棒
磨损
修复
hydro-generator
stator winding bar
abrasion
repair