摘要
电力企业所处的环境和规划模式决定了规划过程中所要遵循的准则和导则。简单介绍了制定不同可靠性设计准则的背景,包括属性、准则和导则的基本概念,制定可靠性准则需要考虑的因素等,分别讨论了在配电网规划中3种处理可靠性准则的规划方式:传统方式、现代方式和过渡方式。
The guidance and standard should be complied during planning stage which is decided according to the circumstances and planning mode of the electric power enterprises.The background of different designing standard for reliability,including property,basic conception of the standard and guidance,and the factors needing to be considered,is briefly introduced.Three standards for reliability as well as their related three planning modes:traditional mode,modern mode and transitional mode are discussed respectively.
出处
《供用电》
2011年第3期9-14,共6页
Distribution & Utilization
关键词
可靠性导则
可靠性准则
规划方式
reliability guidance
reliability standard
planning method