期刊文献+

肋骨骨折多层螺旋CT最佳低剂量扫描参数的选择 被引量:6

Selection of Optimal Low-dose MSCT Scanning Parameters in Rib Fracture
下载PDF
导出
摘要 目的探讨肋骨骨折低剂量多层螺旋CT扫描的最佳参数。方法将30名志愿者随机分为3组,分别行低剂量螺旋CT扫描,管电流分别设置为100 mA、50 mA及25 mA,扫描后行薄层及VR、MPR重建,由三位不同年资医师分别进行影像分析,并进行不同管电流组间统计学秩和检验(Kruskal Wallis检验),选取最佳低剂量扫描参数。再选择10例肋骨骨折患者利用最佳扫描参数进行检查以判断其对于诊断肋骨骨折的可靠性。结果统计学表明,χ2=18.921,P=0.000,三组间差异均有统计学意义。100 mA、50 mA扫描及重建影像显示肋骨结构清晰、完整,噪音小,无伪影,均能达到诊断目的。25 mA由于噪声及伪影的影响,影像不能完全达到诊断目的。50 mA肋骨骨折患者低剂量螺旋CT扫描后处理影像能完整显示肋骨骨折。结论 50mA管电流是肋骨骨折低剂量多层螺旋CT扫描的最佳参数。 Objective To investigate the optimal technical parameters of low-dose MSCT(multi-slice spiral CT) scan in rib fracture.Methods Thirty volunteers were divided into three groups randomly to have low-dose MSCT chest scan with three different tube current of 100 mA,50 mA and 25 mA respectively.Thin-slice,VR and MPR reconstruction were performed.All images were analyzed by three different period service doctors.Kruskal Wallis test was used to choose the optimal technical parameters.Then 10 rib fracture patients had the optimal technical parameter CT scan to analyze it's reliability of diagnosing rib fracture.Results s There were statistical differences among three groups(χ2=18.921,P=0.000).The original and reconstructed images of 100mA、50mA groups could clearly show the rib structure with low noise and no artifacts.The images of 25mA group couldn't meet the need of imaging diagnosis because of the noise and artifacts.Conclusion 50mA low-dose MSCT scan could clearly show rib fracture in patient group.
出处 《中国实验诊断学》 北大核心 2011年第6期1064-1066,共3页 Chinese Journal of Laboratory Diagnosis
关键词 肋骨骨折 多层螺旋CT 低剂量 rib fracture multi-slice spiral CT low-dose
  • 相关文献

参考文献6

  • 1Jelly LM, Evans DR, Easty MJ, et al Radiography versus spiral CT in the eo valuation of eervieothoraeie junction injuries in polyWauma patients who have undergone intubatian [J]. Radiographics, 2000,20 (Spec) : S251.
  • 2Kennedy TC, Miller Y, Prindiville S. Screening for lung cancer: revisedand the role of sputum cytology and fluorescence bronchoscopy in high risk group [ J ]. Chest, 2000,7 : 72.
  • 3魏宝杰,张镭,翟仁友,等.低剂量双螺旋CT薄层扫描筛查早期癌初步研究[J].JCT,2002,1l:21.
  • 4Naidich DP, Marshadl CH, Gribbin C, et al. Low-dose CT of the lungs: preliminary observations [ J ]. Radiology, 1990, 175 : 729.
  • 5郭文梅,申丽盈,马春华.多层面螺旋CT低剂量在骨盆扫描中的应用研究[J].医学理论与实践,2003,16(12):1402-1403. 被引量:6
  • 6王淑丽,王林森,孙鼎元,邓欣,耿欣,李健,刘志刚,郭林,贾志红.多层螺旋CT在肋骨微细骨折诊断中的应用价值[J].中华放射学杂志,2005,39(12):1289-1292. 被引量:133

二级参考文献15

  • 1崔炜,戴汝平,郭玉印,吕滨,何沙,荆宝莲,白桦,任力.超高速CT评价心室容积准确性的研究[J].中华放射学杂志,1997,31(2):93-95. 被引量:27
  • 21 Naidich DP, Marshallch, Gfibbinc, et al. Low does CT of the Lungs Preliminary observations. Radiology, 1990, 175:729 - 731.
  • 3Dward Lnickoloff, Philip, Oaiderson. Radiation Exposure to Patients from CT: Reality, Public, Perception, and Policy ,AJR,2001, 177:285.
  • 4Lane Fdomlelly, Kathleen HE mery, Alan Sbrody, et al. Minimizing Radiation Dose for Pediatric Body. Applications of Single Detector Helical CT: Strafe - giesata Large Children, s Hospital .AJR,2001,176:303.
  • 5James GR, Avenel Ernest MS, Calzetti, Walter Huda, et al. Radiation Exposure an Image quality in Chest CT Examinations . :AJR, 2001,177:279.
  • 6Vogel M,White PA,Redington AN.In vitro validation of right ventricular volume measurement by three dimensional echocardiography.Br Heart J,1995,74:460-463.
  • 7Vogel M,Gutberlet M,Dittrich S,et al.Comparison of transthoracic three dimensional echocardiography with magnetic resonance imaging in the assessment of right ventricular volume and mass.Heart,1997,78:127-130.
  • 8Dirksen MS,Bax JJ,de Roos A,et al.Usefulness of dynamic multislice computed tomography of left ventricular function in unstable angina pectoris and comparison with echocardiography.Am J Cardiol,2002,90:1157-1160.
  • 9Juergens KU,Grude M,Fallenberg EM,et al.Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease.AJR,2002,179:1545-1550.
  • 10Ringertz HG,Rodgers B,Lipton MJ,et al.Assessment of human right ventricular cast volume by CT and angiocardiography.Invest Radiol,1985,20:29-32.

共引文献137

同被引文献51

  • 1庄玉忠,方佩君,葛箐芳,俞忠辉,林丽萍,万凯明.多层螺旋CT三维成像在急性肋骨骨折诊断中的应用[J].放射学实践,2005,20(11):996-998. 被引量:33
  • 2盛蕾,王霞,孔庆奎.不同重建方法对多层螺旋CT诊断肋骨骨折准确性的影响[J].医学影像学杂志,2007,17(2):194-197. 被引量:27
  • 3Zachenhofer 1,Cejna M,Schuster A, et al. Image quality and artefact generation post-cerebral aneusm clipping using a 64-row muhislice computer tomography angiography ( MSCTA ) technology : A retro- spective study and review cff the literature[ J ]. Clin Neurol Neuro- surg,2010,112(5 ) :386 - 391.
  • 4Gerardin E,Tollard E, Derrey S,et al. Usefulness of multislice com- puterized tomographic angiography in the postoperative evaluation of patients with clipped aneurysms[ J]. Acta Neurochir(Wien) ,2010, 152 (5) :793 - 802.
  • 5van Werkhoven JM, Schuijf JD, Gaemperli O, et al. Incremental prog- nostic value of multi-slice computed tomography coronary angiogra- phy over coronary artery calcium scoring in patients with suspected coronary artery disease [ J ]. Eur Heart J, 2009, 30 ( 21 ) : 2622 - 2629.
  • 6van Werkhoven JM, Gaemperli O, Schuijf JD, et aL Multislice com- puted tomography coronary angiography for risk stratifieation in pa- tients with an intermediate pretest likelihood [ J ]. Heart, 2009,95 (19) : 1607 - 1611.
  • 7Gerardin E,Daumas Duport B,Tollard E,et al. Usefulness of multi- slice computerized tomography angiography in preoperative diagnosis of ruptured cerebral aneurysms [ J ]. J Neuroradio1,2009,36 ( 5 ) : 278 - 284.
  • 8茹欢孟,段润卿,吴利江.MSCT、三维重建、CR-PACS显示器诊断肋骨骨折的临床应用[J].实用放射学杂志,2008,24(7):1004-1005. 被引量:9
  • 9彭德昌,龚洪翰,刘润,王敏君,陈业媛,肖香佐.多层螺旋CTMIP、CPR重建在肋骨骨折医学鉴定的应用[J].实用放射学杂志,2010,26(7):1062-1063. 被引量:38
  • 10罗晚辉.肋骨骨折检查的CR与传统X线片对照[J].中国实用医药,2010,5(34):77-78. 被引量:2

引证文献6

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部