期刊文献+

下颈椎经关节螺钉钉棒系统形式固定的临床研究 被引量:2

Clinical study of posterior transarticular fixation with rod-screw in the lower cervical vertebrae
下载PDF
导出
摘要 目的:探讨下颈椎经颈后正中入路采用经关节螺钉钉棒形式固定的应用。方法:自2005年7月至2009年7月,在11例下颈椎创伤性骨折脱位,9例颈椎管狭窄的后路固定中应用经关节螺钉以Vertex钉棒系统形式固定。其中男16例,女4例;年龄29~76岁,平均51岁,均行颈椎后路经关节螺钉内固定植骨融合、减压(其中3例结合前路手术)。经关节螺钉置钉方法:以侧块中心点内侧1mm为进钉点,进钉角度在矢状面上尾倾35°~40°,在冠状面上外倾15°~20°。术后摄颈椎X线片,评价螺钉位置和颈椎的序列和植骨融合情况。结果:共置入经关节螺钉88枚,其中10枚于C3,4,20枚于C4,5,32枚于C5,6,26枚于C6,7。术中所有螺钉均成功置入,未出现椎动脉、神经根和脊髓损伤等置钉相关并发症且均获得植骨融合,无内固定断裂失败。JOA评分:术后1周平均改善率55.8%,其中优5例,良7例,可7例,差1例,优良率为60%;术后3个月平均改善率为74.5%,其中优6例,良8例,可6例,优良率75%。术前与术后3个月JOA评分比较有统计学差异。结论:后路经关节螺钉钉棒形式内固定是一种有效的下颈椎固定形式,经过初步临床应用发现具有固定可靠,操作简单等优点。但这一新的固定形式,尚需长期的临床随访和观察。 Objective:To explore the effects of posterior transarticular fixation with rod-screw in treating fracture and dislocation,spinal stenosis of lower cervical vertebrae.Methods:From July 2005 to July 2009,11 patients with cervical fracture and dislocation and 9 with spinal stenosis of lower cervical vertebrae underwent operation with transarticular fixation with rod-screw(Vertex system).There were 16 cases male and 4 cases female,ranging in age from 29 to 76 years with an average of 51 years.All patients underwent decompression,internal fixation and fusion through posterior approach(combined with anterior approach in 3 cases).The method of insertion of screw:the starting point located in medial 1 mm of the midpoint of the lateral mass,angle in sagittal plane was 15°-20° of caudal clinism and in coronal plane was 35°-40° of external clinism.The position of screws,the cervical array,bone graft and fusion were observed by X-ray films.Results:A total of 88 transarticular screws were successfully inserted,10 screws located in C3,4,20 in C4,5,32 in C5,6,26 in C6,7.There were no complications related to screw insertion,such as injury of the vertebral artery,nerve roots and the spine cord.All patients obtained bone fusion without internal fixation breaking.The improvement rate of JOA was 55.8% at the 1st week after operation,5 cases got excellent results,7 good,7 fair,1 poor;the improvement rate of JOA was 74.5%,at the 3rd month after operation,6 cases got excellent results,8 good,6 fair.There was significant difference in the JOA between before operation and at the 3rd month after operation.Conclusion:The transarticular screw fixation with rod-screw in the lower cervical spine is an effective fixation,which has advantages of rigid stability,convenience to perform,and can reduce operative risk in initial application,but the long-term follow-up is very necessary.
出处 《中国骨伤》 CAS 2011年第7期538-540,共3页 China Journal of Orthopaedics and Traumatology
关键词 颈椎 椎管狭窄 脊柱骨折 脱位 内固定器 并发症 Cervical vertebrae Spinal stenosis Spinal fractures Dislocations Internal fixators Complications
  • 相关文献

参考文献6

二级参考文献43

  • 1马维虎,刘观燚,徐荣明,孙韶华,黄雷,阮永平.颈椎后路经关节螺钉钢板内固定术在下颈椎骨折脱位中的应用[J].中华创伤杂志,2007,23(1):29-33. 被引量:20
  • 2刘观燚,徐荣明,马维虎,阮永平.下颈椎关节突关节的解剖学测量与经关节螺钉固定的关系[J].中国脊柱脊髓杂志,2007,17(2):140-144. 被引量:22
  • 3刘观燚,徐荣明,马维虎,阮永平,孙韶华,黄雷.Anatomic comparison of transarticular screws with latera mass screws in cervical vertebrae[J].Chinese Journal of Traumatology,2007,10(2):67-71. 被引量:6
  • 4Roy-Camille R.Mazel C.Saillant G.Treatment of cervical spine injuries by a posterior osteosynthesis with plates and screws.In:Kehr P.Weidner A,eds.Cervical spine.Vienna:Springer-Verlag,1987,163
  • 5Roy-Camille R.Saillant G.Chirurgie du rachis cervical:luxation-fracture des articulaires.Nouvelle Presse Medicale,1972,1:2484-2485
  • 6Takayasu M,Hara M,Yamauchi K,et al.Transarticular serew fixation in the middle and lower cervical spine. Technical note.J Neurosurg, 2003, 99(1 Suppl): 132-136.
  • 7Klekamp JW, Ugbo JL, Heller JG, et al. Cervical transfacet versus lateral mass screws: a biomechanical comparison. J Spinal Disord, 2000, 13: 515-518.
  • 8Jeanneret B, Magerl F, Ward EH, et al. Posterior stabilization of the cervical spine with hook plates. Spine, 1991, 16(Suppl) : 56-63.
  • 9Graham AW, Swank ML, Kinard RE, et al. Posterior cervical arthrodesis and stabilization with a lateral mass plate. Clinical and computed tomographic evaluation of lateral mass screw placement and associated complications. Spine, 1996, 21:323-328.
  • 10Wellman B J, Follett KA, Traynelis VC. Complications of posterior articular mass plate fixation of the subaxial cervical spine in 43 consecutive patients. Spine, 1998, 23: 193-200.

共引文献25

同被引文献33

  • 1池永龙,徐华梓,林焱,黄其杉,毛方敏,倪文飞.微创经皮椎弓根螺钉内固定治疗胸腰椎骨折的初步探讨[J].中华外科杂志,2004,42(21):1307-1311. 被引量:125
  • 2胡宁,方煌,罗永湘,王娟.椎弓根螺钉植入导向器的研制及体外应用研究[J].中国修复重建外科杂志,2005,19(3):221-223. 被引量:9
  • 3陈刚,马勇,王彪,杭晨.后外侧颈椎间盘突出症后入路髓核摘除术疗效与安全性评价[J].医学研究杂志,2006,35(12):101-103. 被引量:1
  • 4Kim YJ,Lenke LG,Kim J,et al. Comparative analysis of pedicle screw versus hybrid instrumentation in posterior spinal fusion of adolescent idiopathic scoliosis [ J ]. Spine, 2006,31 : 291-298.
  • 5Liljenqvist UR, Allkemper T, Hackenberg L, et al. Analysis of ver- tebral morphology in idiopathic scoliosis with use of magnetic reso- nance imaging and multiplanar reconstruction [J ]. J Bone Joint Surg Am, 2002,84 : 359-368.
  • 6Vaccaro AR, Rizzolo S J, Allardyce TJ, et al. Placement of pedicle screws in the thoracic spine. Part I : Morphometric analysis of the thoracic vertebrae [J ] J Bone Joint Surg Am, 1995,77-1193-1199.
  • 7Panjabi MM ,O'Holleran JD ,Crisco JJ 3rd ,et al. Complexity of the thoracic spine pedicle anatomy [J ]. Eur Spine J, 1997,6:19-24.
  • 8Gertzbein SD,Robbins RE. Accuracy of pedicular screw place- ment in vivo [J ]. Spine, 1990,15:11-14.
  • 9Dvorak M, MacDonald S, Gurr KR, et al. An anatomic,radiograph- ic,and biomechanical assessment of extrapedicular screw fixation in the thoracic spine[J]. Spine, 1993,18 : 1689-1694.
  • 10Farber GL,Place HM ,Mazur RA ,et al. Accuracy of pedicle screw placement in lumbar fusions by plain radiographs and computed tomography [ J ]. Spine, 2002,20 : 1494-1499.

引证文献2

二级引证文献16

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部