期刊文献+

Investigation of flexible electrodes modified by TiN,Pt black and IrO_x 被引量:4

Investigation of flexible electrodes modified by TiN,Pt black and IrO_x
原文传递
导出
摘要 TiN, platinum (Pt) black and iridium oxide are introduced to the stimulating sites to improve the performance of the flexible electrode. Low temperature process is used to fabricate the modifying films. TiN is coated on the gold sites by magnetron sputtering while platinum black and iridium oxide are coated by electroplating and electrodeposifion, respectively. The impedance of the electrode decreases dramatically after modification. The combined analysis of surface morphology and cyclic voltammograms (CV) in phosphate buffer saline (PBS) solution indicates that the modified electrode sites have larger electrode-electrolyte capacitance and smaller faradic resistance than unmodified sites, thus they have smaller electrochemical impedances.
出处 《Science China(Technological Sciences)》 SCIE EI CAS 2011年第9期2305-2309,共5页 中国科学(技术科学英文版)
基金 supported by the Major National Scientific Research Plan (Grant Nos. 2011CB933203, 2011CB933102) National Natural Science Foundation of China (Grant Nos. 61036002, 60877035, 31070965)
关键词 flexible electrodes modification IMPEDANCE cyclic voltammograms (CV) 修饰电极 修改 铂黑 黑色 氧化物涂层 电化学阻抗 磷酸盐缓冲液
  • 相关文献

参考文献1

  • 1LIN JianHui1,2,3, WU XiaoMing1,2,3,4, HUANG PengSheng1,2, FENG Lei5, REN TianLing1,2 & LIU LiTian1,2 1 Institute of Microelectronics, Tsinghua University, Beijing 100084, China,2 Tsinghua National Laboratory for Information Science and Technology, Beijing 100084, China,3 Yangtze Delta Region Institute of Tsinghua University, Jiaxing 314050, China,4 State Key Laboratory of Transducer Technology, Chinese Academy of Sciences, Shanghai 200050,China,5 Department of Biomedical Engineering, Tsinghua University, Beijing 100084, China.Development of silicon-based microelectrode array[J].Science China(Technological Sciences),2009,52(8):2391-2395. 被引量:3

二级参考文献12

  • 1Whalen J J III.Platinum nanowire microelectrode arrays for neu- rostimulation applications: fabrication, characterization, and in-vitro retinal cell stimulation. . 2004
  • 2Wise K D.Wireless integrated microsystems: coming breakthroughs in health care. IEDM’06 . 2006
  • 3J.E Hetke.3-D Silicon Probe Array with Hybrid Polymer Interconnect for Chronic Cortical Recording. Proceedings of the 1st International IEEE EMBS Conference on Neural Engineering . 2003
  • 4Richard A.Normann,Edwin M.Maynard,Patrick J.Rousche,et al.A Neural Interface for a Cortical Vision Pros-thesis. Vision Research . 1999
  • 5Peter Norlin,Maria Kindlundh,Aliette Mouroux,Ken Yoshida and Ulrich G Hofmann.A 32-site neural recording probe fabricated by DRIE of SOI substrates. Journal of Micromechanics and Microengineering . 2002
  • 6Kindlundh M,Norlin P,Hofmann UG.A neural probe process enabling variable electrode configurations. Sensors and Actuators . 2004
  • 7Sergio Martinoia,Paolo Massobrio,Macro Bove,and Giuseppe Massobrio.Cultured neurons coupled to microelectrode arrays: circuit models, simulations and experimental data. IEEE Transactions on Biomedical Engineering . 2004
  • 8McAdams,ET,Jossinet,J.The detection of the onset of electrode-electrolyte interface impedance nonlinearity: a theoretical study. IEEE Transactions on Biomedical Engineering . 1994
  • 9Zsolt Kerner and Tam&#xe,s Pajkossy.Impedance of rough capacitive electrodes: the role of surface disorder. Journal of Electrocardiology . 1998
  • 10Kerner Z,Pajkossy T.On the origin of capacitance dispersion of rough electrodes. Electrochimica Acta . 2000

共引文献2

同被引文献6

引证文献4

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部