通过对盘锦某催化剂厂在生产催化剂过程中产生的高浓度氨氮废水静态吹脱试验,总结出水温、pH、水力停留时间、气水比、1号脱氮剂用量等相关参数对吹脱效率的影响。
The static test was conducted to treat the waste water of high concentration ammonia from the catalyst production process in Panjin catalyst plant. The resuhs were summed up on the temperature, pH, hydraulic retention time, gas-water ratio, 1# de-nitrogen dosage and other related parameters on the stripping efficiency.