石墨炉原子吸收法测定地表水中镉的不确定度评定 被引量:2

Evaluation of Uncertainty of Measuring Cadmium in Surface Water by Graphite Furnace Atomic Absorption Spectrometry
下载PDF
导出
摘要 为保证农作物生长环境中重金属的检测质量,科学地评定检测结果的分散性,依据国家标准方法和测量不确定度评定与表示的理论,以农业灌溉区地表水为例,评定了石墨炉原子吸收法测定地表水中镉的不确定度。测得地表水样中镉的浓度为2.15μg/L,扩展不确定度U95=0.19μg/L(k=2)。结果表明,利用该法测定地表水中的重金属时,对其合成标准不确定度的主要贡献来自仪器分析过程。 Aiming to ensure the quality of determining heavy metals from growth environment of crops,and evaluate the dispersancy of results,the uncertainty of measuring cadmium(Cd) in surface water collected from an agricultural irrigating area by graphite furnace atomic absorption spectrometer was evaluated on the base of the theory of evaluation and expression of uncertainty in measurement.Cd was detected at a concentration of 2.15 μg/L in the surface water,and 0.19 μg/L of the expanded uncertainty,U95(k=2),was obtained in the method.The result indicated that the combined standard uncertainty of using such method to determine heavy metals in surface water mainly derived from instrument analysis.
出处 《湖北农业科学》 北大核心 2011年第14期2963-2965,2973,共4页 Hubei Agricultural Sciences
基金 国家自然科学基金青年基金项目(40903040) 广东高校优秀青年创新人才培育项目(LYM09107)
关键词 不确定度 石墨炉原子吸收法 地表水 uncertainty graphite furnace atomic absorption spectrometry surface water cadmium
  • 相关文献

参考文献8

  • 1中国实验室国家认可委员会.化学分析中不确定度的评估指南[M].北京:中国计量出版社,2006.
  • 2JJF1059-1999.测量不确定度评定与表示[S].[S].,..
  • 3GB/T27025-2008检测和校准实验室能力的通用要求[S].
  • 4ISO/IECl7025:2005.检测和校准实验室认可准则[S].
  • 5国家环境保护总局和水和废水监测分析方法编委会.水和废水监测分析方法[M].第四版(增补版)北京:中国环境科学出版社.2002.
  • 6JJG646-2006.中华人民共和国国家计量检定规程移液器[S].2006.
  • 7JJG196-2006中华人民共和国国家计量检定规程常用玻璃量器[S].2006.
  • 8兰建丽,徐风云,兰建敏.原子荧光法测定水中砷的不确定度评定[J].食品与发酵工业,2005,31(7):114-116. 被引量:11