摘要 Bali Tourism Development Corporation's lagoon (BTDC lagoon) has been used for treating wastewaters that come from all facilities available in the Nusa Dua Resort tourist area. Reuse of the lagoon effluent is limited for some applications due to salt and suspended solid contents. Application of an integrated membrane system for improving the water quality of the lagoon effluent which is suitable for various uses is under consideration. In this work an ultraflltration (UF) pilot performance for possible pretreatment of Reverse Osmosis (RO) was investigated. The results showed that permeate quality was stable (less than 0.5 NTU), regardless of concentrating and diluting retentate in each cycle and fouling for a long duration of operation. However, the water quality obtained with this membrane was not enough to be directly used. The permeate quality obtained from the UF system fulfils the requirement for the optimal operation of reverse osmosis. Moreover, appropriate intermittent-backwash operation was fairly effective to maintain the fluxes at a reasonable level.
出处 《Journal of Environmental Science and Engineering》 2011年第8期962-970,共9页 环境科学与工程(英文版)
关键词 LAGOON ULTRAFILTRATION wastewater treatment water reuse. 污水处理 试验系统 超滤膜 泻湖 性能 稳定 废物 固体悬浮物
  • 相关文献

参考文献26

  • 1C.R. Steinmann, S. Weinhart, A. Melzer, A combined system of lagoon and constructed wetland for an effective wastewater treatment, Water Research 37 (2003) 2035-2042.
  • 2D. Kaya, F.B. Dilek, C.F. G6kgay, Reuse of lagoon effluents in agriculture by post-treatment in a step feed dual treatment process, Desalination 215 (2007) 29-36.
  • 3J.G. Jacangelo, R.R. Trussell, M. Watson, Role of membrane technology in drinking water treatment in the United States, Desalination 113 (1997) 119-127.
  • 4J.Y. Huang, S. Takizawa, K. Fujita, Pilot-plant study of a high recovery membrane filtration process for drinking water treatment, War. Sci. Tech. 41 (2000) 77-84.
  • 5H. Choi, H.S. Kim, I.T. Yeom, D.D. Dionysiou, Pilot plant study of an ultrafiltration membrane system for drinking water treatment operated in the feed-and-bleed mode, Desalination 172 (2005) 281-291.
  • 6A.S. AI-Amoudi, Factors affecting natural organic matter (NOM) and scaling fouling in NF membranes: A review, Desalination 259 (2010) 1-10.
  • 7A.M. Ravazzini, A.F. van Nieuwenhuijzen, J.H.M.J. van der Graaf, Direct ultrafiltration of municipal wastewater: Comparison between filtration of raw sewage and primary clarifier effluent, Desalination 178 (2005) 51-62.
  • 8M. Fababuj-Roger, J.A. Mendoza-Roca, M.V. Galiana-Aleixandre, A. Bes-Pi& B. Cuartas-Uribe, A. Iborra-Clar, Reuse of tannery wastewaters by combination of ultrafiltration and reverse osmosis after a conventional physical-chemical treatment, Desalination 204 (2007) 219-226.
  • 9F. Zanetti, G. De Luca, R. Sacchetti, Performance of a full-scale membrane bioreactor system in treating municipal wastewater for reuse purposes, Bioresource Technology 101 (2010) 3768-3771.
  • 10S.L. Kim, J.P. Chen, Y.P. Ting, Study on pretreatment for membrane filtration of secondary effluent, Sep. Purif. Technol. 29 (2002) 171-179.

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部