期刊文献+

Imaging performance evaluation in depth-of-interaction PET with a new method of sinogram generation:A Monte Carlo simulation study 被引量:1

Imaging performance evaluation in depth-of-interaction PET with a new method of sinogram generation:A Monte Carlo simulation study
下载PDF
导出
摘要 In conventional PET systems,the parallax error degrades image resolution and causes image distortion.To remedy this,a PET ring diameter has to be much larger than the required size of field of view(FOV),and therefore the cost goes up.Measurement of depth-of-interaction(DOI)information is effective to reduce the parallax error and improve the image quality.This study is aimed at developing a practical method to incorporate DOI information in PET sinogram generation and image reconstruction processes and evaluate its efficacy through Monte Carlo simulation.An animal PET system with 30-mm long LSO crystals and 2-mm DOI measurement accuracy was simulated and list-mode PET data were collected.A sinogram generation method was proposed to bin each coincidence event to the correct LOR location according to both incident crystal indices and DOI positions of the two annihilation photons.The sinograms were reconstructed with an iterative OSMAPEM(ordered subset maximum a posteriori expectation maximization)algorithm.Two phantoms(a rod source phantom and a Derenzo phantom)were simulated,and the benefits of DOI were investigated in terms of reconstructed source diameter(FWHM)and source positioning accuracy.The results demonstrate that the proposed method works well to incorporate DOI information in data processing,which not only overcomes the image distortion problem but also significantly improves image resolution and resolution uniformity and results in satisfactory image quality. In conventional PET systems, the parallax error degrades image resolution and causes image distortion. To remedy this, a PET ring diameter has to be much larger than the required size of field of view (FOV), and therefore the cost goes up. Measurement of depth-of-interaction (DOI) information is effective to reduce the parallax error and improve the image quality. This study is aimed at developing a practical method to incorporate DOI information in PET sinogram generation and image reconstruction processes and evaluate its efficacy through Monte Carlo simulation. An animal PET system with 30-mm long LSO crystals and 2-mm DOI measurement accuracy was simulated and list-mode PET data were collected. A sinogram generation method was proposed to bin each coincidence event to the correct LOR location according to both incident crystal indices and DOI positions of the two annihilation photons. The sinograms were reconstructed with an iterative OSMAPEM (ordered subset maximum a posteriori expectation maximization) algorithm. Two phantoms (a rod source phantom and a Derenzo phantom) were simulated, and the benefits of DO1 were investigated in terms of reconstructed source diameter (FWHM) and source positioning accuracy. The results demonstrate that the proposed method works well to incorporate DOI information in data processing, which not only overcomes the image distortion problem but also significantly improves image resolution and resolution uniformity and results in satisfactory image quality.
出处 《Nuclear Science and Techniques》 SCIE CAS CSCD 2011年第3期144-150,共7页 核技术(英文)
基金 Supported by Specialized Research Fund of the Doctoral Program of Higher Education(SRFDP 200800031071 ) National Natural Science Foundation of China (No.10975086) National High Technology Research and Development Program("863"Program) of China(No.2006AA020802)
关键词 蒙特卡罗模拟 PET 性能评价 图像分辨率 LSO晶体 成像 图像失真 图像质量 Positron emission tomography (PET), Depth of interaction (DOI), Monte Carlo simulation, Sinogramgeneration, Image reconstruction
  • 相关文献

参考文献22

  • 1Chen C T,Pan X C,Kao C M.United States Patent:US 006528791B1.Mar.4,2003.
  • 2Levin C S,Zaidi H.PET Clin,2007,2:125-160.
  • 3Kao C M,Pan X C,Chen C T.IEEE Trans Nucl Sci,2000,47:1551-1560.
  • 4Shao Y P,Meadors K,Silverman R W,et al.IEEE Trans Nucl Sci,2002,49:649-654.
  • 5Moses W W,Derenzo S E.IEEE Trans Nucl Sci,1994,41:1441-1445.
  • 6Moisan C,Andreaco M S,Rogers J C,et al.IEEE Trans Nucl Sci,1998,45:3030-3035.
  • 7Miyaoka R S,Lewellen T K,Yu H,et al.IEEE Trans Nucl Sci,1998,45:1069-1073.
  • 8Shao Y P,Li H R,Gao K K.Nucl Instrum Methods Phys Res A,580:944-950.
  • 9Yang Y F,Qi J Y,Wu Y B,et al.Phys Med Biol,2009,54:433-435.
  • 10Shao Y P,Yao R T,Ma T Y.Med Phys,2008,35:5829-5840.

同被引文献1

引证文献1

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部