新型多参数水质分析仪流路控制系统的设计 被引量:5

Design of New Streams Control System for Multi-parameter Water Quality Analyzer
下载PDF
导出
摘要 以单片机为核心,运用十联体电磁阀、三通阀和微型步进蠕动泵等流控器件设计新型多流路控制系统。对比测试结果表明,该系统能完成20多种流路切换,进样速度快,加样误差小于1%,能快速、高效地清洗进样通道,并避免交叉污染,而且成本低、不易堵塞、稳定性良好。 A novel multi-stream control system was proposed for multi-parameter water quality analyzer.The MCU-cored system consisting of streams control devices of ten conjoined solenoid valves,three-way valve and step peristaltic micro-pump has characteristics of low cost and less plugging and high stability compared with the streams systems composed of multi-position valve and injector pump.Testing results show that this system can achieve streams switching among over 20 streams,8mL/min sample rate,less than 1% sampling error,a quick cleaning and elimination of cross-contamination.
出处 《化工自动化及仪表》 CAS 北大核心 2011年第4期439-442,共4页 Control and Instruments in Chemical Industry
基金 国家"863"计划项目(2007AA042101) 科技部国际科技合作项目(2007DFC00040)
关键词 流路切换 流路控制 电磁阀 微型蠕动泵 streams switching streams control solenoid micro-pump
  • 相关文献

参考文献9

  • 1金子,冯吉平,张蕾,孙晓成.便携式仪器在水环境监测中的应用[J].东北水利水电,2002,20(9):48-49. 被引量:8
  • 2Chu N,Fan S H.Sequential Injection Kinetic Spectrophotometric Determination of Quaternary Mixtures of Carbamate Pesticides in Water and Fruit Samples Using Artificial Neural Networks for Multivariate Calibration[J].Spectrochimica Acta Part A:Molecular and Biomolecular Spectroscopy,2009,74 (5):1173 ~1181.
  • 3Abdalla M.Sequential Injection Spectrophotometric Determination of Cyanide[J].Flow Injection Anal,2007,24(1):17 ~21.
  • 4Eliana S S.Sequential Injection Spectrophotometric Determination of V (V) in Environmental Polluted Waters[J].Water SA,2009,35(3):283 ~288.
  • 5Jiménez J R.Lab-on-valve for the Automatic Determination of the Total Content and Individual Profiles of Linear Alkylbenzene Sulfonates in Water Samples[J].Electrophoresis,2008,29(1):590 ~ 596.
  • 6Vanloot P.On-line Solid-phase Extraction and Multisyringe Flowinjection Analysis of Al(Ⅲ) and Fe(Ⅲ)in Drinking Water[J].Anal Bioanal Chem,2007,389(5):1595 ~ 1602.
  • 7杨海,陆晓华,陈光东.便携式水质分析仪的研制[J].环境科学与技术,2003,26(2):49-51. 被引量:4
  • 8王奎兰,吴清平,邓金花,蔡淑珍.水质快速分析技术现状及发展趋势[J].现代仪器,2005,11(5):54-56. 被引量:14
  • 9齐文启,陈光,孙宗光.水质环境监测技术和仪器的发展[J].现代科学仪器,2003,20(6):8-12. 被引量:34

二级参考文献12

共引文献52

同被引文献25

  • 1魏康林.基于微型光谱仪的多参数水质检测仪关键技术研究[D].重庆大学.2012
  • 2William H van der Schalie,Tommy R Shedd,Paul L Knechtges,Mark W Widder.Using higher organisms in biological early warning systems for real-time toxicity detection[J].Biosensors and Bioelectronics.2001(7)
  • 3Adela Fernández,Carmen Tejedor,Fernando Cabrera,Andrés Chordi.Assessment of toxicity of river water and effluents by the bioluminescence assay using Photobacterium phosphoreum[J].Water Research.1995(5)
  • 4Michael V Storey, Bram vander Gaag, Brendan P. Bums. Advances in on-line drinking water quality monitoring and early warning systems[J]. Water Research, 2011, 45:741-747.
  • 5Michael V. Storey,Bram van der Gaag,Brendan P. Burns.Advances in on-line drinking water quality monitoring and early warning systems[J]. Water Research . 2010 (2)
  • 6Jahan B. Ghasemi,Ali R. Jalalvand.Multi-wavelength spectrophotometric determination of the protolytic constants of tetracycline hydrochloride in some nonaqueous-water mixed solvents: A solvatochromism study[J]. Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy . 2010 (1)
  • 7任宗明,王涛,白云岭,赵立庭.水质在线安全生物预警系统模拟预警及应用[J].供水技术,2009,3(2):1-3. 被引量:15
  • 8曹学飞,尹少平,印江.嵌入式触摸屏接口电路及驱动设计[J].电力学报,2009,24(5):399-401. 被引量:3
  • 9任宗明,李志良.高锰酸钾及氯化锰对日本青鳉的急、慢性毒性[J].生态毒理学报,2009,4(6):841-846. 被引量:9
  • 10魏康林,温志渝,武新,张中卫,曾甜玲.基于紫外-可见光谱分析的水质监测技术研究进展[J].光谱学与光谱分析,2011,31(4):1074-1077. 被引量:39

引证文献5

二级引证文献31

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部