基于分区电网的多机进相调压效益探析 被引量:4

Voltage Regulation Effects of Leading phase Operation of Multi-generators in District Grids
原文传递
导出
摘要 发电机进相运行是解决系统低谷运行时枢纽点电压偏高的有效手段。针对江苏省2010年实际背景分区电网,选择若干组已投运的机组,以分类分区研究单机进相的调压作用为基础,对多机进相运行进行仿真,分析进相运行对分区关键母线电压的影响和对系统电压的调节作用,并校验多机进相运行时系统的暂态稳定性,探讨分区内多机进相运行的调压能力。 Leading phase operation of generators is an effective method to reduce voltage of the key point which is much high in valley load period.Several generating units in operation in the district grid of Jiangsu province in 2010 were selected as the research targets.Then the research analyzed the influence of leading phase of multi-generators on the key bus voltage based on the voltage regulation effects of leading phase of single-generator in classification and subarea method.The transient stability of leading phase of multi-generators was verified,and the voltage regulation capability of leading phase of multi-generators was analyzed.
出处 《华东电力》 北大核心 2011年第9期1434-1438,共5页 East China Electric Power
基金 国家自然科学基金项目(50877024 50977021) 河海大学自然科学基金资助项目(2009421411) 江苏省电力公司2009年重点科技项目(J2009032)~~
关键词 分区电网 多机进相 调压系数 电压调节 暂态校验 district grid leading phase operation of multi-generators voltage regulation coefficient voltage regulation transient calibration
  • 相关文献

参考文献10

二级参考文献34

  • 1柳焕章.发电机失磁保护的原理及整定计算[J].电力系统自动化,2004,28(14):72-75. 被引量:25
  • 2胡念苏,陈波,周宇阳.汽轮发电机组经济性监测诊断系统中失效参数的处理[J].武汉大学学报(工学版),2003,36(6):91-95. 被引量:1
  • 3马宏忠,李之昆,彭钱.GP法在发电机转子绕组匝间短路诊断中的应用[J].继电器,2004,32(22):16-19. 被引量:6
  • 4刘文锦.水轮发电机定有功状态下静态稳定极限的实用计算方法[J].广东电力,1995,8(3):26-31. 被引量:2
  • 5湖南省电力试验研究所.五强溪等电厂机组进相运行及其湖南电网运行电压的影响研究[M].,1998,12..
  • 6夏道止.电力系统分析[M].西安:西安交通大学出版社,1994..
  • 7Camm EH, Keyhani A, Pillutla S. Development of a neural network model for rotor angle estimation[J]. International Journal of Engineering Intelligent Systems for Electrical Engineering & Communications, 1998, 6(1): 13-18.
  • 8De Mello FP. Measurement of synchronous machine rotor angle from analysis of zero sequence harmonic components of machine terminal voltage[J]. IEEE Trans Power Delivery, 1994, 9(4): 1770-1777.
  • 9Kosterev DN, Esztergalyos J, Stigers CA. Feasibility study of using synchronized phasor measurements for generator dropping controls in the Colstrip System [J]. IEEE Trans Power Systems, 1998, 13(3):755-761.
  • 10Morioka Y, Tomiyama K, Arima H, et al. System separation equipment to minimize power system instability using generator's angular-velocity measurements [J]. IEEE Trans Power Delivery,1993, 8(3): 941-947.

共引文献121

同被引文献28

引证文献4

二级引证文献4

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部