摘要
按照《固定污染源烟气排放连续监测技术规范》(HT/T 75-2007)的要求,以Testo 350XL分析系统为例,介绍了便携式烟气分析系统在燃煤电厂CEMS比对监测的流程,分析实际监测中存在问题,提出了注意事项。
According to requests of standard HT/T 75-2007 Specification for Continuous Emissons Monitoring of flue gas emitted from stationary sources,the application of portable gas analysis system in the area of CEMS in coal-fired power plant was introduced.By analyzing the problems in practical monitoring with Testo 350XL,the items to be pay attention to were put forward.
出处
《电力科技与环保》
2011年第5期57-59,共3页
Electric Power Technology and Environmental Protection
关键词
烟气分析
电厂
烟气排放连续监测系统
gas analysis
power plant
continuous emission monitoring system