以600MW前后墙对冲燃烧锅炉为例,目标为寻求高效率低NOx排放,建立了燃烧优化模型,对各个影响因素进行了分析,并且对性能量;状态量和调节量之间的关系进行了描述。
For 600MW opposed wall firing boiler as an example, the target for high efficiency and low NOx emission, combustion optimization model is established, the impact of various factors are analyzed, and the sexual energy; state quantity and adjusting the relation between quantity are described.