光照模式对复合树脂聚合收缩率和表面硬度的影响 被引量:4

Effects of light-curing modes on the polymerization shrinkage and surface hardness of composite resins
下载PDF
导出
摘要 目的:研究光固化模式对复合树脂聚合收缩率和表面硬度的影响,探讨这些因素的影响对临床工作的指导意义。方法:研究使用填料含量为76%(质量分数)的混合填料复合树脂,选择3种光固化模式固化树脂,分别为高光强模式、低光强模式和软启动模式,每种光固化模式分别固化树脂10 s和20 s。制备树脂聚合收缩样本和表面硬度样本,使用Acuvol聚合收缩仪测定树脂的聚合收缩率(n=7),显微硬度仪测定树脂的表面硬度(n=5)。结果:高光强、低光强、软启动3种光固化模式固化树脂后聚合收缩率分别为2.95%±0.08%/3.06%±0.03%(10 s/20 s)、2.98%±0.12%/3.05%±0.13%(10 s/20 s)、3.03%±0.05%/3.11%±0.07%(10 s/20 s),3者间差异无统计学意义(P>0.05);表面硬度分别为:(36.82±4.45)MPa/(47.58±3.16)MPa(10 s/20 s)、(32.30±1.33)MPa/(41.60±1.83)MPa(10 s/20 s)、(34.56±1.38)MPa/(44.62±2.13)MPa(10 s/20 s),3者间差异有统计学意义(P<0.05),从高向低依次为:高光强模式>软启动模式>低光强模式。光固化输出能量与复合树脂固化后聚合收缩率呈低度正相关(r=-0.363,P=0.018),其与复合树脂固化后表面硬度呈高度正相关(r=-0.890,P<0.001)。结论:高光强模式有利于提高修复体的物理性能;应用软启动模式或低光强模式固化树脂时,应适当延长固化时间以增加光输出能量,使树脂固化后的物理性能不受影响。 Objective: To investigate the effects of light-curing modes on the polymerization shrinkage and surface hardness of resins and to explore the related clinical relevance.Methods: Resins with filler content of 76%(mass fraction) were light-cured by high intensity,low intensity and soft start curing modes for 10 s and 20 s,respectively.Specimens for detecting volumetric shrinkage and surface hardness were prepared.Volumetric shrinkage was measured with Acuvol(n=7) and surface hardness were tested with an indenter(n=5).Results: The volumetric shrinkage of composites cured by high intensity,low intensity and soft-start curing mode was: 2.95%±0.08%/3.06%±0.03%(10 s/20 s),2.98%±0.12%/3.05%±0.13%(10 s/20 s),and 3.03%±0.05%/3.11%±0.07%(10 s/20 s),respectively.No significant difference existed among polymerization shrinkage of composites cured by the three light-curing modes(P0.05).The hardness of composites cured by high intensity,low intensity and soft-start curing mode was:(36.82±4.45) MPa/(47.58±3.16) MPa(10 s/20 s),(32.30±1.33) MPa/(41.60±1.83) MPa(10 s/20 s),and(34.56±1.38) MPa/(44.62±2.13) MPa(10 s/20 s),respectively.There existed significant difference among hardness of composites cured by the three light-curing modes(P0.05).Polymerization shrinkage was correlated with energy density(r=-0.363,P=0.018).Surface hardness was also correlated with energy density(r=-0.890,P0.001).Conclusion: It would be better to use high intensity curing mode to improve the physical properties of restorations.In order to keep the physical properties of composites,it is necessary to prolong the curing time using soft-start/low intensity curing modes to increase the energy density.
出处 《北京大学学报(医学版)》 CAS CSCD 北大核心 2011年第5期770-773,共4页 Journal of Peking University:Health Sciences
基金 国家自然科学基金(50742009 50830101) "十一五"国家科技支撑计划重点项目(2007BAI18B01)~~
关键词 复合树脂 聚合收缩 硬度 Composite resins Polymerization shrinkage Hardness Light
  • 相关文献

参考文献14

  • 1Hofmann N, Denner W, Hugo B, et al. The influence of plasma arc vs. halogen standard or soft-start irradiation on polymerization shrinkage kinetics of polymer matrix composites [ J ]. J Dent, 2003, 31(6) : 383 -393.
  • 2Visvanathan A, Ilie N, Hickel R, et al. The influence of curing times and light curing methods on the polymerization shrinkage stress of a shrinkage-optimized composite with hybrid-type prepolymer fillers-J]. Dent Mater, 2007, 23(7) : 777 -784.
  • 3Yap A, Ng SC, Kiow KS. Soft-start polymerization: Influence on effectiveness of cure and post-gel shrinkage [ J ]. Oper Dent, 2001,26(3): 260-266.
  • 4Lu I-I, Stansbury JW, Bowman CN. Impact of curing protocol on conversion and shrinkage stress [ J ]. J Dent Res, 2005, 84 (9) : 822 - 826.
  • 5Giachetti L, Scaminaci RD, Bambi C, et al. A review of polymerization shrinkage stress: current techniques for posterior direct re- sin restorations[J]. J Contemp Dent Pract, 2006, 7(4) : 79 -88.
  • 6Braga RR, Ballester RY, Ferracane JL. Factors involved in the development of polymerization shrinkage stress in resin-composites: a systematic review[J]. Dent Mater, 2005, 21 (10): 962 - 970.
  • 7Ernst C, Brand N, Frommator U, et al. Reduction of polymeriza- tion shrinkage stress and marginal microleakage using soft-start polymerization [ J ]. J Esthet Restor Dent, 2003, 15 (2) : 93 - 104.
  • 8Watts DC, A1 HA. Intrinsic "soft-start" polymerisation shrinkage- kinetics in an acrylate-based resin-composite [ J]. Dent Mater, 1999, 15(1) : 39 -45.
  • 9Anusavice KJ. PHILLIPS' science of dental materials[ M]. 11th ed. USA : Elsevier Science, 2003.
  • 10Sharp LJ, Sy A, Rui Y, et al. Cure kinetics of composites using video imaging[J]. Am J Dent, 2005, 18(2) : 141 -144.

二级参考文献14

  • 1Charton C,Colon P,Pla F.Shrinkage stress in light-cured composite resins:influence of material and photoactivation mode[J].Dent Mater,2007,23(8):911-920.
  • 2Giachetti L,Scaminaci RD,Bambi C,et al.A review of polymerization shrinkage stress:current techniques for posterior direct resin restorations[J].J Contemp Dent Pract,2006,7(4):79-88.
  • 3Sharp LJ,Choi IB,Lee TE,et al.Volumetric shrinkage of composites using video-imaging[J].J Dent,2003,31(2):97-103.
  • 4Ellakwa A,Cho N,Lee IB.The effect of resin matrix composition on the polymerization shrinkage and rheological properties of experimental dental composites[J].Dent Mater,2007,23(10):1229-1235.
  • 5Schneider L,Cavalcante LM,Consani S,et al.Effect of co-initiator ratio on the polymer properties of experimental resin composites formulated with camphorquinone and phenyl-propanedione[J].Dent Mater,2009,25(3):369-375.
  • 6Schneider LF,Consani S,Sakaguchi RL,et al.Alternative photoinitiator system reduces the rate of stress development without compromising the final properties of the dental composite[J].Dent Mater,2009,25(5):566-572.
  • 7Uyama S,Irokawa A,Iwasa M,et al.Influence of irradiation time on volumetric shrinkage and flexural properties of flowable resins[J].Dent Mater J,2007,26(6):892-897.
  • 8Anusavice K J.PHILLIPS'science of dental materials[M].11th ed.Florida,USA:Elsevier Science,2003.
  • 9Labella R,Lambrechts P,Van MB,et al.Polymerization shrinkage and elasticity of flowable composites and filled adhesives[J].Dent Mater,1999,15(2):128-137.
  • 10Kwon YH,Kang SI,Hur B,et al.Effect of irradiation mode on polymerization of dental composite resins[J].J Biomed Mater Res B Appl Biomater,2006,78(2):253-258.

共引文献3

同被引文献62

  • 1孙海燕,仇丽鸿.硬化牙本质的复合树脂黏结修复研究进展[J].中国实用口腔科杂志,2009,2(5):306-308. 被引量:3
  • 2王玉秋,崔广庆,刘涛,刘新建,岳维海,许重奋.牙刷质量、刷牙方法与牙齿楔状缺损的关系[J].中华口腔医学杂志,1995,30(3):169-171. 被引量:27
  • 3崔晓燕,彭红,伍江慧.自酸蚀粘结剂在楔状缺损修复中的临床评价[J].临床口腔医学杂志,2006,22(9):556-557. 被引量:2
  • 4Malhotra N, Mala K. Light-curing considerations for resin-based composite materials: a review. Part I Compend Contin Educ Dent,2010,31 (7) : 498-505,506,508.
  • 5Fahmy N, Naguib I-I, Guindy JE. Effect of light-emitting diode ( LED ) curing modes on resin/dentin bond strength. J Prosthodont ,2009,18 ( 8 ) : 670-675.
  • 6Foxton RM, Pereira PN, Masatoshi N, et al. Long-term durability of the dual-cure resin cement/silicon oxide ceramic bond. J Adhes Dent,2002,4(2) : 125-135.
  • 7Vaidyanathan TK, Vaidyanathan J. Recent advances in the theory and mechanism of adhesive resin bonding to dentin: a critical review. J Biomed Mater Res B Appl Biomater, 2009, 88 ( 2 ) : 558-578.
  • 8Pashley DH, Ciucchi B, Sano H, et al. Bond strength versus dentine structure: a modelling approach. Arch Oral Biol, 1995, 40(12) : 1109-1118.
  • 9Sano H,Takatsu T, Ciucchi B, et al. Nanoleakage : leakage within the hybrid layer. Oper Dent,1995,20( 1 ) : 18-25.
  • 10Spencer P, Swafford JR. Unprotected protein at the dentin-adhesive interface. Quintessence Int, 1999,30 ( 7 ) : 501-507.

引证文献4

二级引证文献21

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部