东二风井抽风机高压变频调速节能改造方案 被引量:1

Reformation Scheme of Energy Saving with High-voltage Frequency Conversion Speed Regulation of Exhaust Fan of Dong'er Air Shaft
下载PDF
导出
摘要 介绍了抽风机高压变频调速节能基本原理、东二风井抽风机高压变频调速节能改造方案及改造效果。东二风井抽风机变频调速采用"一拖二"手动旁路方式,采用一台变频器传动两台抽风机电动机中的一台变频运行,另一台工频运行。运行结果表明,该方案的节电率约为62%。 The paper introduced basic principle of energy saving with high-voltage frequency conversion speed regulation of exhaust fan,and reformation scheme and effect of energy saving with high-voltage frequency conversion speed regulation in Dong'er air shaft.The frequency conversion speed regulation system of exhaust fan of Dong'er air shaft used "one driving two" manual bypass mode which uses a frequency convertor to drive motors of two fans with one running in variable frequency and the other running in power frequency.The running result showed the scheme saved energy of about 62%.
作者 李树荣
出处 《工矿自动化》 2011年第11期108-110,共3页 Journal Of Mine Automation
关键词 矿井 抽风机 变频调速 节能改造 mine exhaust fan frequency conversion speed regulation energy saving reformation
  • 相关文献

参考文献5

二级参考文献6

  • 1韩安荣.通用变频器及应用[M].北京:机械工业出版社,2007.
  • 2张卫斌.凝泵变频自动控制的实施及优化[c]//2010年全国发电厂热工自动化年会论文集.北京:电力行业热工自动化技术委员会,2010.
  • 3黄元培 张学.变频器应用技术及电动机调速[M].北京:人民邮电出版社,1998..
  • 4齐义禄.节能降耗技术手册[M].中国电力出版社,1998.7..
  • 5ZINVERT系列高压变频调速系统培训教材[R].广州:广州智光电机有限公司,2004.
  • 6王贺岑,邹文华,马淮军,刘江涛,许明峰,韩平.风机变频改造节能技术在火电厂的应用研究[J].中国电力,2002,35(2):70-74. 被引量:45