期刊文献+

光固化复合树脂凝胶玻璃化后固化收缩量评价 被引量:1

Evaluation of laser triangulation method for measurement of post-gel shrinkage and post-vitrifi-cation shrinkage in composite resins
原文传递
导出
摘要 目的评价光固化复合树脂在凝胶点后特别是玻璃化后的固化收缩量,以期为深入研究光固化复合树脂的固化收缩特性提供新的评价方法。方法利用本实验室自主研制开发的一种基于激光测距技术的固化收缩测量仪,获得5种光固化复合树脂自光照开始后300s内的固化收缩量一时间曲线和固化收缩速率.时间曲线,并通过收缩速率-时间曲线计算凝胶点和转变点V以及凝胶点后及玻璃化后的固化收缩量。结果5种光固化复合树脂的凝胶点为0.77—1.59s,差异有统计学意义(P〈0.01);转变点V为1.99~6.33s,差异有统计学意义(P〈0.01);凝胶点后收缩量为33.35~53.18μm,差异有统计学意义(P〈0.01);玻璃化后收缩量为16.43—30.58μm,差异有统计学意义(P〈0.01);总收缩量为39.25~64.84μm,差异有统计学意义(P〈0.01)。5种光固化复合树脂凝胶点后收缩量及玻璃化后收缩量的顺序与总收缩量的顺序有所不同。结论通过动态测量光固化复合树脂固化收缩量,可推测凝胶点和转变点V,从而获得更具有实用意义的复合树脂固化收缩特性评价参考值。 Objective To employ a laser triangulation method for measuring post-gel and postvitrifi-eation polymerization shrinkage of composite resins. Methods A novel experimental set-up capable of measuring real-time shrinkage strain was utilized. Total shrinkage of the five composite resins was measured. The measurements of post-gel and post-vitrification linear shrinkage as a function of the gel-point and vitrification transition point were also carried out in the study. Results Gel point of the five composite resins ranged from 0. 77 s to 1.59 s, while vitrification transition point ranged from 1.99 s to 6. 33 s. Postgel shrinkage ranged from 33.35 μm to 53.18 μm and post-vitrification shrinkage ranged from 16.43 μm to 30. 58 μm. Total shrinkage ranged from 39. 25 p,m to 64. 84 μm. Significant differences in the gel point and vitrification transition point among the five composite resins were found( P 〈 0. 01 ). Significant differences in the post-gel shrinkage, post-vitrification shrinkage and total shrinkage among the five composite resins were found(P 〈0. 01 ). The ranking of post-gel and post-vitrification shrinkage of these composite was different from that of their total shrinkage. Conclusions Laser triangulation method is suitable for measuring clinically significant post-gel and post-vitrification shrinkage.
出处 《中华口腔医学杂志》 CAS CSCD 北大核心 2011年第11期684-687,共4页 Chinese Journal of Stomatology
关键词 复合树脂类 玻璃化 固化收缩 激光测距技术 Composite resins Vitrification Polymerization shrinkage Iaser ranging
  • 相关文献

参考文献17

  • 1Villat C, Pradelle-Plasse N, Picard B, et al. Characterization method of photopolymerization kinetics of two dental composite resins using two types of light sources. Mater Sei Eng C, 2008, 28(5-6) : 971-976.
  • 2Kleverlaan C J, Feilzer AJ. Polymerization shrinkage and contraction stressof dental resin composites. Dent Mater, 2005, 21(12) :1150-1157.
  • 3Rosin M, Urban AD, Gartner C, et al. Polymerization shrinkage- strain and microleakage in dentin-bordered cavities of chemically and light-cured restorative materials. Dent Mater, 2002,18 (7) : 521-528.
  • 4韩冰,董艳梅,王晓燕,田福聪,高学军.用聚合收缩仪Acuvol测定填料含量对复合树脂聚合收缩率的影响[J].北京大学学报(医学版),2010,42(5):582-585. 被引量:4
  • 5Papadogiannis D, Kakaboura A, Palaghias G, et al. Setting characteristics and cavity adaptation of low-shrinking resin composites. Dent Mater, 2009, 25 ( 12 ) : 1509-1516.
  • 6Cehreli MC, Cehreli ZC, Akca K. Impact of similarity in chemical composition of light-polymerized resin composites on post-gel strains and interface integrity. J Mater Sci Mater Med, 2007,18(6) :1053-1060.
  • 7吴剑波,骆清铭.激光三角法在生物医学领域中的若干应用[J].激光技术,2006,30(1):1-4. 被引量:4
  • 8郑刚,徐恒昌,赵奇.固化光源的种类对复合树脂充填材料固化收缩量的影响[J].中国生物医学工程学报,2002,21(3):246-250. 被引量:8
  • 9Atai M, Watts DC, Atai Z. Shrinkage strain-rates of dental resin- monomer and composite systems. Biomaterials, 2005, 26 (24) : 5015-5020.
  • 10Dewaele M, Asmussen E, Peutzfeldt A, et al. Influence of curing protocol on selected properties of light-curing polymers: degree of conversion, volume contraction, elastic modulus, and glass transition temperature. Dent Mater, 2009, 25 (12) : 1576-1554.

二级参考文献23

  • 1[1]Phillips RW. Science of dental materials[M]. Washington; W.B.Saunders Tents. EDRTION company.1996,292-294.
  • 2[2]Tanoue N, Matsumura H, et al. Properties of four composite veneering materials polymerized with different laboratory photo-curing units[J]. Oral Rehabilitation. 1998,25(5):358-364.
  • 3[3]Sfondrini MF, Cacciafesta V, et al. Effects of conventional and high-intensity light-curing on enamel shear bond strength of composite resin and resin-modified glass-ionomer[J]. Amer J Orthodon Dentof Orthoped. 2001,119(1):30-35.
  • 4[4]国际标准ISO 4049-2000 DentistryPolymer-based filling restorative and luting materials[S].
  • 5[6]Watts DC, Hindi AAL. Intrinsic`soft-start' polymerisation shrinkage-kinetics in an acrylate-based resin-composite[J]. Dent Materials,1999,15(1):39-45.
  • 6平泽忠.治疗用照射器の特性[J].The journal of dent engineer,1999,(130):1-5.
  • 7稻井纪通等.高出力照射器とレジンの硬化[J].J dental engineer,2000,(132):13-18.
  • 8[9]de Dee AJ, Feilzer AJ, et al. True linear polymerization shrinkage of unfilled resins and composites determined with a linometer[J]. Dent Materials.1993,9(1):11-14.
  • 9Charton C,Colon P,Pla F.Shrinkage stress in light-cured composite resins:influence of material and photoactivation mode[J].Dent Mater,2007,23(8):911-920.
  • 10Giachetti L,Scaminaci RD,Bambi C,et al.A review of polymerization shrinkage stress:current techniques for posterior direct resin restorations[J].J Contemp Dent Pract,2006,7(4):79-88.

共引文献12

同被引文献20

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部