期刊文献+

剩余污泥浓缩脱水投药量优化和模型建立 被引量:1

Dosage optimization and modeling of concentration and dehydration of surplus sludge
原文传递
导出
摘要 应用高分子阳离子絮凝剂(CPF-100)和聚丙烯酰胺(PAM)对污水厂剩余污泥进行浓缩脱水实验,研究表明:CPF-100的浓缩脱水效果优于PAM;当CPF-100投加量为1.16‰时,污泥沉降性能改善程度为37.51%;且在CPF-100投加量逐渐增大的初始阶段,污泥沉降性能改善程度随投加量的增加而增大,但CPF-100投加量也不宜过大,当CPF-100投加量超过1.16‰后,反而会使浓缩脱水效果变差。同时,建立了污泥沉降性能改善程度与絮凝剂CPF-100投加量、沉降时间之间的数学模型,其能较好地反映污水厂剩余污泥的浓缩脱水效果。 CPF-100 and PAM were used to improve the performance of surplus sludge concentration and dehydration in a wastewater treatment plant, and CPF-100 was better than PAM. When the dosage of CPF-100 was 1.16‰, the concentration and dehydration efficiency increased 37.51% than no coagulant. The perform- ance of concentration and dehydration increased with the beginning of CPF-100 dosage increase. However, when the dosage of CPF-100 was more than 1. 16‰, the concentration and dehydration performance worsened with an increase in the CPF-100 dosage. Moreover, a mathematical model was proposed and calibrated with the experi- mental data. The proposed model dealt with the relationship between the concentration and dehydration efficien- cy, CPF-100 dosage and settling time. The model was appropriate and feasible to describe the performance of surplus sludge concentration and dehydration in wastewater treatment plants.
作者 李振华
出处 《环境工程学报》 CAS CSCD 北大核心 2011年第12期2797-2800,共4页 Chinese Journal of Environmental Engineering
基金 华中农业大学自主创新基金(博士科研启动)项目(52204-10195) 国家高技术研究发展计划(863)项目(2005AA601010-01)
关键词 剩余污泥 CPF-100 聚丙烯酰胺 浓缩脱水 模型 surplus sludge CPF-100 PAM concentration and dehydration model
  • 相关文献

参考文献6

二级参考文献18

  • 1陆在宏,吴今明,唐意祥.给水厂排泥水处理工艺研究(上)[J].给水排水,1993,19(10):5-8. 被引量:13
  • 2党永光,陈吕军,汪诚文,柯细勇,贾建军,王东升,刘伟岩,郝风岭,常江,陈颜斌.污泥浓缩脱水投药量优化控制的研究[J].给水排水,2005,31(11):15-18. 被引量:11
  • 3田秀敏,刘开连,黎琦,马殿旗,楼上游,胡仕明.带式压滤机脱水系统加药自动控制[J].环境科学,1996,17(4):31-32. 被引量:5
  • 4Dentel S K. Congditioning, thickening, and dewatering: research update/research needs. Water Science and Technology, 2001, 44(10):9-18.
  • 5Mikkelsen L H, Keiding K. Effects of solids concentration on activated sludge deflocculation, conditioning and dewatering. Water Science and Technology,2001, 44(2 - 3) :417-425.
  • 6Sievers M, Schroeder C, Borrnann H, et al. Automation in sludge dewatering by novel on- line characterization of flocculation. Water Science and Technology , 2003, 47(2):157-164.
  • 7Chu C P, Lee D J. Moisture distribution in sludge: effects of polymer conditioning. Journal of Environmental Engineering, 1999, 125(4) :340.
  • 8Wu C C , Huang C, Lee D J. Effects of polymer dosage on alum sludge dewatering characteristics and physical properties, Environmental Engineering, 1997, 122(1 - 3) :89-96.
  • 9Jeremy E Hall, Anna Zmyslowska. Development of sludge treatment and disposal strategies for large conurbations: case study-Warsaw[J]. Wat. Sic. Tech, 1997;36(11):291- 298.
  • 10P Aarne Vesilind, Cheng--Chao Hsu. Limits of sludge dewater ability[J]. Wat.Res.,1997,36(18):87-91.